Safety relay for emergency stop, safety doors, light grids up to SIL 3, Cat. 4, PL e, 1- or 2-channel operation, cross-circuit detection, can be retriggered, off-/on delay of 0.2 s to 300 s, 5 enabling current paths, US = 24 V DC, plug-in screw terminal block

Liên hệ mua hàng

Hãng sản xuất: PHOENIX CONTACT

Chất lượng: Mới 100%

Bảo hành: Chính hãng

Chứng từ: CO/CQ, hóa đơn VAT

Liên hệ(SĐT/Zalo): 0933612627

Product type Safety relays
Product family PSRmini
Application Emergency stop
Safety door
Light grid
Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Times
Typical response time < 50 ms (automatic start)
< 50 ms (manual, monitored start)
Typ. starting time with Us 500 ms (with Us when controlled via A1)
Typical release time < 25 ms (when controlled via S12 and S22 (only for undelayed contacts))
< 10 ms (when controlled via A1; applicative deactivation via A1/A2 is not permitted)
Delay time range 0.2 s ... 300 s ±5 % (can be set for 47/48/58)
Restart time < 1 s (Boot time)
Recovery time 500 ms (following demand of the safety function)
Maximum power dissipation for nominal condition 8.1 W (At US = 30 V, IL² = 108 A²)
Nominal operating mode 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage 250 V AC
Rated surge voltage/insulation Basic insulation 4 kV between all current paths and housing
Safe isolation, reinforced insulation 6 kV between (A1, A2, S11, S12, S21, S22, S34, M1) and enabling current path (13/14) and enabling current path (23/24/34) and enabling current path (47/48/58)
Supply
Designation A1/A2
Rated control circuit supply voltage US 19.2 V DC ... 30 V DC
Rated control circuit supply voltage US 24 V DC -20 % / +25 %
Rated control supply current IS typ. 80 mA
Power consumption at US typ. 1.92 W
Inrush current typ. 28 A (Δt = 30 µs at Us)
Filter time 1 ms (For the logic. At A1 in the event of voltage dips at Us )
Protective circuit Serial protection against polarity reversal; Suppressor diode
General
Limit frequency min. 0 Hz
max. 1 Hz
Digital: Sensor circuit (S12, S22)
Description of the input safety-related sensor inputs
Number of inputs 2
Input voltage range "0" signal 0 V DC ... 5 V DC
Input voltage range "1" signal 11 V DC ... 30 V DC
Input current range "0" signal 0 mA ... 2 mA
Inrush current < 11 mA (typically with US)
Filter time max. 3 ms (Test pulse width of low test pulses)
min. 21 ms (Test pulse rate for low test pulse)
Concurrence
Limit frequency min. 0 Hz
max. 1 Hz
Max. permissible overall conductor resistance 150 Ω
Protective circuit Varistor
Current consumption < 4.5 mA (typically with US)
Digital: Start circuit (S34)
Description of the input non-safety-related
Number of inputs 1
Input voltage range "0" signal 0 V DC ... 5 V DC
Input voltage range "1" signal 11 V DC ... 30 V DC
Input current range "0" signal 0 mA ... 2 mA
Inrush current < 8.6 mA (typically with US)
Filter time max. 1 ms (Test pulse width of low test pulses)
min. 21 ms (Test pulse rate for low test pulse)
Limit frequency min. 0 Hz
max. 1 Hz
Max. permissible overall conductor resistance 150 Ω
Protective circuit Varistor
Current consumption < 3.2 mA (typically with US)
Relay: Enabling current paths (13/14, 23/24/34, 47/48/58)
Output description 2 N/O contacts each in series, safety-related, floating
Number of outputs 3 (undelayed: 13/14, 23/24/34)
2 (delayed: 47/48/58)
Contact type 5 enabling current paths
Contact material AgCuNi +0.2 µm ... 0.4 µm Au / AgSnO2 +0.2 µm Au
Switching voltage min. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Switching capacity min. 60 mW
Inrush current min. 5 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-1 4 A (24 V (DC13))
3 A (230 V (AC 15))
Limiting continuous current 6 A
Sq. Total current 108 A2 (observe derating)
Switching frequency 0.5 Hz (depending on the set delay time)
Mechanical service life 10x 106 cycles
Output fuse 6 A gL/gG
4 A gL/gG (for low-demand applications)
Signal: M1
Output description PNP
non-safety-related
Number of outputs 1
Voltage approx. 23 V DC (US - 1 V)
Current max. 100 mA
Maximum inrush current 500 mA (Δt = 10 ms at Us)
Protective circuit Suppressor diode
Short-circuit protection Yes
Clock: S11, S21
Output description PNP
non-safety-related
Number of outputs 2
Voltage corresponds to US
Current max. 100 mA
Maximum inrush current 500 mA (Δt = 10 ms at Us)
Protective circuit Suppressor diode
Short-circuit protection Yes
Connection technology
pluggable yes
Conductor connection
Connection method Screw connection
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG 24 ... 12
Stripping length 7 mm
Screw thread M3
Tightening torque 0.5 Nm ... 0.6 Nm
Status display 5 x bi-color LED
Width 22.5 mm
Height 112.2 mm
Depth 114.5 mm
Housing material Polyamide
Safety data
Stop category 0
1
Safety data: EN ISO 13849
Category 4
Performance level (PL) e (4 A DC13; 3 A AC15; 8760 switching cycles/year)
Safety data: IEC 61508 - High demand
Equipment type Type B
Safety Integrity Level (SIL) 3
Probability of a hazardous failure per hour (PFHD) 1,00 x 10-9 (4 A DC13; 3 A AC15; 8760 switching cycles/year)
Proof test interval 240 Months
Duration of use 240 Months
Safety data: IEC 61508 - Low demand
Equipment type Type B
Safety Integrity Level (SIL) 3
Probability of a hazardous failure on demand (PFDAVG) 5.03 x 10-5
Proof test interval 36 Months
Duration of use 240 Months
Ambient conditions
Degree of protection IP20
Min. degree of protection of inst. location IP54
Ambient temperature (operation) -35 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Maximum altitude ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
Shock 10g (operation), 15g (transport)
Vibration (operation) 10 Hz ... 150 Hz, 2g
CE
Identification CE-compliant
Air clearances and creepage distances between the power circuits
Standards/regulations EN 60664-1
Mounting type DIN rail mounting
Assembly instructions See derating curve
Mounting position vertical or horizontal
Connection method Screw connection

Sản phẩm thịnh hành

Máy nén Embraco NTX6238U 843JA72 2172W

Máy nén Embraco NTX6238U 843JA72 2172W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2446W

Máy nén Embraco NTX6238U 843JA72 2446W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2735W

Máy nén Embraco NTX6238U 843JA72 2735W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2841W

Máy nén Embraco NTX6238U 843JA72 2841W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 1868W

Máy nén Embraco NTX6233U 843FA72 1868W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2088W

Máy nén Embraco NTX6233U 843FA72 2088W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2348W

Máy nén Embraco NTX6233U 843FA72 2348W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2425W

Máy nén Embraco NTX6233U 843FA72 2425W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1702W

Máy nén Embraco NTX6225UV 843HD72 1702W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1978W

Máy nén Embraco NTX6225UV 843HD72 1978W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2161W

Máy nén Embraco NTX6225UV 843HD72 2161W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2236W

Máy nén Embraco NTX6225UV 843HD72 2236W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ: