      MINI MCR-2-RTD-UI-PT-C     -     Resistance thermometer measuring transducer   Phoenix Contact

MINI MCR-2-RTD-UI-PT-C - Resistance thermometer measuring transducer Phoenix Contact

Mã sản phẩm: 2902051

Danh mục: PHOENIX CONTACT, Switch, Measure and Monitor Phoenix Contact,

Configurable temperature transducer with plug-in connection technology for connecting 2, 3, and 4-conductor resistance thermometers and resistance-type sensors. Configurable via DIP switch or software. push-in connection technology, order configuration

Liên hệ mua hàng

Hãng sản xuất: PHOENIX CONTACT

Chất lượng: Mới 100%

Bảo hành: Chính hãng

Chứng từ: CO/CQ, hóa đơn VAT

Liên hệ(SĐT/Zalo): 0933612627

Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Product type Temperature transmitter
Product family MINI Analog Pro
Type Signal conditioner
Configuration DIP switches
Software
App
Insulation characteristics
Overvoltage category II
Pollution degree 2
Electrical isolation 3-way isolation
Protective circuit Transient protection
Step response (0–99%) 200 ms (2-conductor)
500 ms (3-conductor)
500 ms (4-conductor)
Maximum temperature coefficient 0.01 %/K
Transmission error resistance-type sensor 2 Ω
Transmission error resistance thermometer 0.1 % * 350 K / set measuring range; 0.1 % > 350 K (Pt/Ni)
0.3 % * 200 K / set measuring range; 0.3 % > 200 K (Cu)
Electrical isolation Input/output/power supply
Rated insulation voltage 300 Vrms
Test voltage 3 kV AC (50 Hz, 60 s)
Insulation Reinforced insulation according to IEC/EN 61010-1
Supply
Supply voltage range 9.6 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Typical current consumption 32 mA (24 V DC)
63 mA (12 V DC)
Power consumption ≤ 850 mW (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
Signal
Number of inputs 1
Measurement
Number of inputs 1
Configurable/programmable Yes
Sensor types (RTD) that can be used Pt, Ni, Cu sensors
Temperature measuring range -200 °C ... 850 °C (Range depends on sensor type, range can be set freely via software or in increments from -150°C to 850°C via DIP switches)
Temperature measuring range ≥ 20 K
Sensor input current approx. 200 µA
Max. permissible overall conductor resistance ≤ 25 Ω (Per line, RTD in 3- or 4-conductor technology)
≤ 50 Ω (adjustable, RTD in 2-conductor technology)
Linear resistance measuring range 0 Ω ... 4000 Ω (Minimum measuring span: 10% of the selected measuring range)
Connection technology 2-, 3-, 4-conductor
Signal: Voltage/current
Number of outputs 1
Configurable/programmable Yes
Voltage output signal 0 V ... 5 V (via DIP switch)
1 V ... 5 V (via DIP switch)
0 V ... 10 V (via DIP switch)
10 V ... 0 V (via DIP switch)
0 V ... 10.5 V (can be set via software)
Max. voltage output signal approx. 12.3 V
Non-load voltage < 17.5 V
Current output signal 0 mA ... 20 mA (via DIP switch)
4 mA ... 20 mA (via DIP switch)
20 mA ... 0 mA (via DIP switch)
20 mA ... 4 mA (via DIP switch)
0 mA ... 21 mA (can be set via software)
Max. current output signal 24.6 mA
Short-circuit current < 31.5 mA
Load/output load voltage output ≥ 10 kΩ
Load/output load current output ≤ 600 Ω (at 20 mA)
Ripple < 10 mVrms
< 10 mVrms (at 600 Ω)
Resolution, outputs (voltage) 1 mV
Resolution, outputs (current) 2 µA
Behavior in the event of a sensor error configurable
Connection method Push-in connection
Stripping length 10 mm
Conductor cross section rigid 0.2 mm² ... 2.5 mm² (with ferrule)
0.14 mm² ... 2.5 mm² (without ferrule)
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 12 (flexible)
Ex installation (EPL) Gc
Div. 2
Data: IFS interface
Connection method Micro USB type B
Status display Green LED (supply voltage)
Error indication Red LED
Width 6.2 mm
Height 109.81 mm
Depth 119.2 mm
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
Housing material PBT
Ambient conditions
Degree of protection IP20 (not assessed by UL)
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Altitude ≤ 2000 m
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
CE
Certificate CE-compliant
ATEX
Identification  II 3 G Ex ec IIC T4 Gc
Certificate BVS 20 ATEX E 024 X
UKCA Ex (UKEX)
Identification  II 3 G Ex ec IIC T4 Gc
Certificate PxCIF21UKEX2902049X
IECEx
Identification Ex ec IIC T4 Gc
Certificate IECEx BVS 20.0017X
UL, USA/Canada
Identification UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
Shipbuilding approval
Certificate DNV GL TAA00002UA
EAC Ex
Identification  2Ex ec IIC T4 Gc
Certificate BY/112 02.01 TP012 103.01 00079
DNV GL data
Temperature B
Humidity B
Vibration A
EMC A
Enclosure Required protection according to the Rules shall be provided upon installation on board
Noise immunity EN 61000-6-2
Note When being exposed to interference, there may be minimal deviations.
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Comments Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 0.06 %
Fast transients (burst)
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 0.1 %
Surge current load (surge)
Standards/regulations EN 61000-4-5
Conducted interference
Designation Conducted interferences
Standards/regulations EN 61000-4-6
Typical deviation from the measuring range final value 0.07 %
Electrical isolation 3-way isolation
Mounting type DIN rail mounting
Assembly instructions The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail.
Mounting position any

Sản phẩm thịnh hành

Máy nén Embraco NTX6238U 843JA72 2172W

Máy nén Embraco NTX6238U 843JA72 2172W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2446W

Máy nén Embraco NTX6238U 843JA72 2446W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2735W

Máy nén Embraco NTX6238U 843JA72 2735W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2841W

Máy nén Embraco NTX6238U 843JA72 2841W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 1868W

Máy nén Embraco NTX6233U 843FA72 1868W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2088W

Máy nén Embraco NTX6233U 843FA72 2088W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2348W

Máy nén Embraco NTX6233U 843FA72 2348W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2425W

Máy nén Embraco NTX6233U 843FA72 2425W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1702W

Máy nén Embraco NTX6225UV 843HD72 1702W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1978W

Máy nén Embraco NTX6225UV 843HD72 1978W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2161W

Máy nén Embraco NTX6225UV 843HD72 2161W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2236W

Máy nén Embraco NTX6225UV 843HD72 2236W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ: