AC operation
Supply system configuration Star network (TN, TT, IT (PE))
Nominal input voltage range 100 V AC ... 240 V AC
Input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
115 V AC ... 240 V AC ±10 % (UL)
Derating < 100 V AC (1 %/V)
2.5 %/K, > 60 °C
Typical national grid voltage 120 V AC
230 V AC
Voltage type of supply voltage AC
Inrush current < 17 A (25 °C)
Inrush current integral (I2t) < 0.5 A2s
Frequency range (fN) 50 Hz ... 60 Hz ±10 %
Mains buffering time typ. 27 ms (120 V AC)
typ. 28 ms (230 V AC)
Current consumption 2.6 A (100 V AC)
2.2 A (120 V AC)
1.2 A (230 V AC)
1.1 A (240 V AC)
Protective circuit Transient protection; Varistor
Power factor (cos phi) 0.95 (230 V AC)
Device mains fuse 6.3 A internal (device protection)
Recommended breaker for input protection 6 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE < 3.5 mA
DC operation
Input voltage range 100 V DC ... 240 V DC ±10 %
160 V DC ... 240 V DC ±10 % (UL)
Derating < 140 V DC (1 %/V)
Voltage type of supply voltage DC
Current consumption 2.7 A (100 V DC)
1.1 A (240 V DC)
Efficiency typ. 94.5 % (120 V AC)
typ. 95.5 % (230 V AC)
Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN) 10 A
Dynamic Boost (IDyn.Boost) max. 15 A (5 s)
No. of channels 4
Nominal current per channel 1 A
2 A
3.8 A
4 A
6 A
8 A
10 A
Waiting time after switch off of a channel 5 s
Switch-on delay of the channels 100 ms
Short-circuit-proof yes
Derating 60 °C ... 70 °C
Crest factor typ. 1.75 (120 V AC)
typ. 1,7 (230 V AC)
Output power (PN) 240 W
Output power (PDyn. Boost) max. 360 W (5 s)
Connection in parallel no
Connection in series No
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 35 V DC
Residual ripple typ. 50 mVPP (with nominal values)
Control deviation < 1 % (change in load, static 10 % ... 90 %)
< 3 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Rise time ≤ 1 s (UOut = 10 % ... 90 %)
Minimum no-load power dissipation < 1.2 W (120 V AC)
Maximum no-load power dissipation < 1.3 W (230 V AC)
Minimum nominal load power dissipation < 14.5 W (120 V AC)
Power loss nominal load max. < 12 W (230 V AC)
Integrated fuse protection yes
Signal relay 13/14
Position 3.x
Position marking 3.1 (13), 3.2 (14)
Switch contact (floating) OptoMOS
Switching voltage max. 30 V DC (SELV)
Current carrying capacity max. 100 mA
State condition UOut > 21 V DC and IOut < 0.9 x IN (Contact closed)
UOut < 21 V DC or IOut > 0.9 x IN  (averaging over 60 s) (Contact open)
Input
Position 1.x
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 4 mm²
1.5 mm² (recommended)
flexible 0.2 mm² ... 2.5 mm²
1.5 mm² (recommended)
flexible with ferrule without plastic sleeve 0.25 mm² ... 2.5 mm²
1.5 mm² (recommended)
flexible with ferrule with plastic sleeve 0.25 mm² ... 1.5 mm²
1.5 mm² (recommended)
rigid (AWG) 24 ... 12 (Cu)
16 (recommended)
Stripping length 10 mm (rigid/flexible)
8 mm (Ferrule)
Output
Position 2.x
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 4 mm²
1.5 mm² (recommended)
flexible 0.2 mm² ... 2.5 mm²
1.5 mm² (recommended)
flexible with ferrule without plastic sleeve 0.25 mm² ... 2.5 mm²
1.5 mm² (recommended)
flexible with ferrule with plastic sleeve 0.25 mm² ... 1.5 mm²
1.5 mm² (recommended)
rigid (AWG) 24 ... 12 (Cu)
16 (recommended)
Stripping length 10 mm (rigid/flexible)
8 mm (Ferrule)
Output
Position 2.x
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 4 mm²
1.5 mm² (recommended)
flexible 0.2 mm² ... 2.5 mm²
1.5 mm² (recommended)
flexible with ferrule without plastic sleeve 1.5 mm² (recommended)
flexible with ferrule with plastic sleeve 0.25 mm² ... 1.5 mm²
1.5 mm² (recommended)
rigid (AWG) 24 ... 12 (Cu)
16 (recommended)
Stripping length 10 mm (rigid/flexible)
8 mm (Ferrule)
Signal
Position 3.x
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 1.5 mm²
0.5 mm² (recommended)
flexible 0.2 mm² ... 1.5 mm²
0.5 mm² (recommended)
flexible with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (Cu)
0.5 mm² (recommended)
flexible with ferrule with plastic sleeve 0.25 mm² ... 0.75 mm²
0.5 mm² (recommended)
rigid (AWG) 24 ... 16 (Cu)
20 (recommended)
Stripping length 10 mm (rigid/flexible)
8 mm (Ferrule)
Communication
Position 5.x
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 1.5 mm²
0.5 mm² (recommended)
flexible 0.2 mm² ... 1.5 mm²
0.5 mm² (recommended)
flexible with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm² (Cu)
0.5 mm² (recommended)
flexible with ferrule with plastic sleeve 0.25 mm² ... 0.75 mm²
0.5 mm² (recommended)
rigid (AWG) 24 ... 16 (Cu)
20 (recommended)
Stripping length 10 mm (rigid/flexible)
8 mm (Ferrule)
IO-Link
Specification V1.1
Interface IO-Link
Number of interfaces 1
Connection method Push-in connection
Position 5.x
Position marking 5.1 (L+), 5.2 (C/Q), 5.3 (L-)
Transmission physics 3-wire, standard industrial cable
Reverse polarity protection yes
Transmission speed 230.4 kbps (COM3)
Cycle time 2 ms
Electrical isolation yes
Amount of process data 6 Byte (Input data)
Device ID 262657dec/ 0x040201hex
Vendor ID 00B0hex / 176dez
Types of signaling LED DC OK – signal state operation (UN = 24 V DC, IOut = IN)
Function Visual operating state display
Color Yellow, green (bicolor LED)
LED off Supply voltage input AC not present (Off)
LED on (green), DC OK UOut > 21 V DC and IOut < 0.9 x IN (On (green), DC OK)
LED on (yellow), IOut > 90% UOut > 21 V DC and IOut > 0.9 x IN (On (yellow), IOut > 90% )
LED on (red), ISHORT UOut < 21 V DC and IOut > 0.9 x IN (On (red), ISHORT)
LED on (flashing red) OVP UOUT > OVP (Over voltage protection) (On (flashing red))
Number of phases 1.00
Insulation voltage input/output 3 kV AC (type test)
3 kV AC (routine test)
Product type Power supply
Product family TRIO POWER
MTBF (IEC 61709, SN 29500) > 1300000 h (25 °C)
> 860000 h (40 °C)
> 400000 h (60 °C)
Environmental protection directive RoHS Directive 2011/65/EU
WEEE
Reach
Insulation characteristics
Protection class I
Degree of pollution 2
Dimensional drawing
Width 68 mm
Height 135 mm
Depth 132 mm
Depth Device depth (DIN rail mounting) 125 mm
Installation dimensions
Installation distance right/left (active) 15 mm / 15 mm
Installation distance right/left (passive) 0 mm / 0 mm (≤ 40 °C)
Mounting type DIN rail mounting
Assembly instructions alignable: 0 mm horizontally, 30 mm vertically
Mounting position horizontal DIN rail NS 35, EN 60715
With protective coating No
Flammability rating according to UL 94 V0 (Housing, terminal blocks)
Hood version Polycarbonate
Side element version Aluminum
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Ambient temperature (start-up type tested) -40 °C
Maximum altitude ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Shock (operation) 18 ms, 30g, per spatial direction (IEC 60068-2-27)
Vibration (operation) 10 Hz ... 50 Hz, amplitude ±0.2 mm (IEC 60068-2-6)
50 Hz to 150 Hz, 2.3 g, 90 min.
Overvoltage category
EN 61010-1 III (≤ 2000 m)
II (≤ 5000 m)
Overvoltage category
EN 61010-2-201 III (≤ 2000 m)
II (≤ 5000 m)
Safety of power supply units up to 1100 V (insulation distances)
Standards/specifications DIN EN 61558-2-16
Electrical safety
Standards/specifications IEC 61010-2-201 (SELV)
Electronic equipment for use in power installations
Standards/specifications EN 50178/VDE 0160 (PELV)
Safety for measurement, control, and laboratory equipment
Standards/specifications IEC 61010-1
Protective extra-low voltage
Standards/specifications IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Safe isolation
Standards/specifications IEC 61558-2-16
IEC 61010-2-201
Limitation of harmonic line currents
Standards/specifications EN 61000-3-2
UL
Identification UL/C-UL Listed UL 61010-1
UL
Identification UL/C-UL Listed UL 61010-2-201
ANSI/UL
Identification PROCESS CONTROL EQUIPEMENT FOR HAZARDOUS LOCATIONS
(EN)  This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D, Hazardous Locations, or non-hazardous locations only.
(FR)  Cet appareil convient uniquement pour une utilisation en atmosphères explosibles de classe I, division 2, groupes A, B, C et D ou en atmosphères non explosibles.
(EN)  WARNING: Explosion Hazard - Do not connect or disconnect equipment unless power has been switched off or the area is known to be non-hazardous.
(FR)  AVERTISSEMENT : risque d'explosion - ne pas connecter ou déconnecter les équipements sauf si l'alimentation a été coupée ou si la zone est réputée non dangereuse.
(EN)  If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
(FR)  Si l'équipement est utilisé d'une manière non spécifiée par le fabricant, la protection fournie par cet équipement peut être altérée.
(EN)  This equipement must be installed in a suitable, tool secured/key locked enclosure.
(FR)  Cet équipement doit être installé dans un boîtier approprié, verrouillé par une clé ou dont l'ouverture nécessite l'utilisation d'un outil.
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Interference emission Interference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
Noise immunity Immunity in accordance with EN 61000-6-1 (residential), EN 61000-6-2 (industrial)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Conducted noise emission EN 55016
EN 61000-6-3 (Class B)
Noise emission EN 55016
EN 61000-6-3 (Class B)
DNV GL conducted interference Class A
Additional text Area power distribution
DNV GL noise radiation Class B
Additional text Bridge and deck area
Harmonic currents
Standards/regulations EN 61000-3-2
EN 61000-3-2 (Class A)
Frequency range 0 kHz ... 2 kHz
Flicker
Standards/regulations EN 61000-3-3
EN 61000-3-3
Frequency range 0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 6 kV (Test Level 3)
Discharge in air 8 kV (Test Level 3)
Comments Criterion B
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 1 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1 GHz ... 6 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input asymmetrical 2 kV (Test Level 3)
Output asymmetrical 2 kV (Test Level 4)
Signal asymmetrical 1 kV (Test Level 3)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input symmetrical 4 kV (Test Level 4)
asymmetrical 2 kV (Test Level 4)
Output symmetrical 1 kV (Test Level 3)
asymmetrical 2 kV (Test Level 3)
Signal asymmetrical 1 kV (Test Level 2)
Comments Criterion A
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)
Voltage dips
Standards/regulations EN 61000-4-11
Voltage 230 V AC
Frequency 50 Hz
Voltage dip 70 %
Number of periods 25 periods
Additional text Class 3
Comments Criterion A
Voltage dip 40 %
Number of periods 10 periods
Additional text Class 3
Comments Criterion B
Voltage dip 0 %
Number of periods 1 period
Additional text Class 3
Comments Criterion A
Criteria
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Sản phẩm thịnh hành

Máy nén Embraco NTX6238U 843JA72 2172W

Máy nén Embraco NTX6238U 843JA72 2172W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2446W

Máy nén Embraco NTX6238U 843JA72 2446W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2735W

Máy nén Embraco NTX6238U 843JA72 2735W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2841W

Máy nén Embraco NTX6238U 843JA72 2841W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 1868W

Máy nén Embraco NTX6233U 843FA72 1868W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2088W

Máy nén Embraco NTX6233U 843FA72 2088W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2348W

Máy nén Embraco NTX6233U 843FA72 2348W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2425W

Máy nén Embraco NTX6233U 843FA72 2425W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1702W

Máy nén Embraco NTX6225UV 843HD72 1702W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1978W

Máy nén Embraco NTX6225UV 843HD72 1978W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2161W

Máy nén Embraco NTX6225UV 843HD72 2161W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2236W

Máy nén Embraco NTX6225UV 843HD72 2236W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ: