category Tất cả danh mục
Menu
      SACCBP-FSB-5CON-PG9/0,5-900SCO     -     Device connector, rear mounting   Phoenix Contact

SACCBP-FSB-5CON-PG9/0,5-900SCO - Device connector, rear mounting Phoenix Contact

Mã sản phẩm: 1437601

Danh mục: PHOENIX CONTACT, Kết nối (Connect) Phoenix Contact,

Bus system flush-type female connector, INTERBUS, 5-pos., M12, shielded, B-coded, SPEEDCON, rear/screw mounting with Pg9 thread, with 0.5 m bus line

Liên hệ mua hàng

Hãng sản xuất: PHOENIX CONTACT

Chất lượng: Mới 100%

Bảo hành: Chính hãng

Chứng từ: CO/CQ, hóa đơn VAT

Liên hệ(SĐT/Zalo): 0933612627

General The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Safety note
Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by Phoenix Contact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
Mounting type Rear mounting
Connection method Cable lug connection
Product type Circular connectors (device side)
Number of positions 5
Sensor type INTERBUS
No. of cable outlets 1
Shielded yes
Coding B
Insulation characteristics
Overvoltage category II
Degree of pollution 3
Flammability rating according to UL 94 V0
Seal material FKM
Contact material CuZn
Contact surface material Ni/Au
Contact carrier material PA 6.6
Material for screw connection Nickel-plated brass
Outer sheath, material PUR
Rated surge voltage 1.5 kV
Contact resistance ≤ 3 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 48 V AC
60 V DC
Nominal current IN 4 A
Transmission medium Copper
Conductor connection
Connection method Cable lug connection
Type of contact Crimp contacts
Tightening torque 2 Nm
3 Nm
Mechanical data
Insertion/withdrawal cycles > 100
Connection 1
Head design Socket
Head cable outlet straight
Head thread type M12
Coding B
Connection 2
Head design free cable end
Cable length 0.5 m
INTERBUS [900]
Dimensional drawing
Cable weight 70 kg/km
Number of positions 6
Shielded yes
Cable type INTERBUS [900]
Conductor structure 3 x 2 x 0.22 mm²
Signal speed 0.66 c
Conductor structure signal line 32x 0.10 mm
AWG signal line 24
Conductor cross section 3x 2x 0.22 mm²
External cable diameter 8 mm
Outer sheath, material PUR
External sheath, color may green RAL 6017
Conductor material Bare Cu litz wires
Material wire insulation PE
Single wire, color green-yellow, white-brown, gray-pink
Twisted pairs 2 cores to the pair
Overall twist 3 pairs to the core
Insulation resistance ≥ 5 GΩ*km
Coupling resistance < 250.00 mΩ/m (at 30 MHz)
Loop resistance ≤ 159.80 Ω/km
Wave impedance 120 Ω ±20 % (at 64 kHz)
100 Ω ±15 % (with 1 MHz)
Cable capacity ≤ 60 nF/km (At 800 Hz)
Nominal voltage, cable 250 V (Peak value, not for high-power applications)
Test voltage Core/Core 1500 Vrms
Test voltage Core/Shield 1000 Vrms
Minimum bending radius, fixed installation 7.5 x D
Minimum bending radius, flexible installation 15 x D
Max. bending cycles 5000000
Near end crosstalk attenuation (NEXT) ≥ 61 dB (at 772 kHz)
≥ 59 dB (with 1 MHz)
≥ 55 dB (at 2 МHz)
≥ 50 dB (at 4 МHz)
≥ 46 dB (at 8 МHz)
≥ 44 dB (at 10 MHz)
≥ 41 dB (at 16 MHz)
≥ 40 dB (at 20 МHz)
Shield attenuation ≤ 15 dB/km (at 256 kHz)
≤ 24 dB/km (at 772 kHz)
≤ 27 dB/km (with 1 MHz)
≤ 52 dB/km (at 4 МHz)
≤ 84 dB/km (at 10 MHz)
≤ 112 dB/km (at 16 MHz)
≤ 119 dB/km (at 20 МHz)
Flame resistance according to VDE 0472, Part 4, test type B
according to IEC 60332-1
Ambient temperature (operation) -40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)
Ambient conditions
Degree of protection IP67 (When plugged in)
IP65 (When plugged in)
IP65/IP67
Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
M12
Standards/specifications IEC 61076-2-101

Sản phẩm thịnh hành

Máy nén Embraco NTX6238U 843JA72 2172W

Máy nén Embraco NTX6238U 843JA72 2172W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2446W

Máy nén Embraco NTX6238U 843JA72 2446W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2735W

Máy nén Embraco NTX6238U 843JA72 2735W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2841W

Máy nén Embraco NTX6238U 843JA72 2841W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 1868W

Máy nén Embraco NTX6233U 843FA72 1868W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2088W

Máy nén Embraco NTX6233U 843FA72 2088W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2348W

Máy nén Embraco NTX6233U 843FA72 2348W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2425W

Máy nén Embraco NTX6233U 843FA72 2425W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1702W

Máy nén Embraco NTX6225UV 843HD72 1702W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1978W

Máy nén Embraco NTX6225UV 843HD72 1978W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2161W

Máy nén Embraco NTX6225UV 843HD72 2161W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2236W

Máy nén Embraco NTX6225UV 843HD72 2236W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ: