| Cable length |
Free input (0.2 ... 40.0 m) |
| PUR halogen-free gray [280] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable type |
PUR halogen-free gray |
| Cable type (abbreviation) |
280 |
| PUR, black, 5th conductor gray [115] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 / 10493 (80°C/300 V) |
| Cable weight |
35 kg/km |
| Cable type |
PUR, black, 5th conductor gray |
| Short symbol |
Li9Y11Y-HF |
| Cable type (abbreviation) |
115 |
| External cable diameter |
5 mm ±0.15 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
black-gray RAL 7021 |
| Thickness, outer sheath |
approx. 0.7 mm |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
5x 0.34 mm² |
| Material, filler |
PP |
| Material wire insulation |
PP |
| Thickness, insulation |
≥ 0.21 mm |
| Wire diameter incl. insulation |
1.27 mm ±0.02 mm |
| Single wire, color |
brown, white, blue, black, gray |
| Overall twist |
5 cores, twisted |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
≤ 58 Ω/km |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
4000000 |
| Bending radius |
50 mm |
| Traversing path |
10 m |
| Traversing rate |
3 m/s |
| Acceleration |
10 m/s² |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with DIN UL-Style 20549 |
| |
in accordance with UL 758/1581 FT2 |
| Other resistance |
partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
| |
hydrolysis and microbe resistant |
| |
Resistant to salt water |
| |
Low adhesion |
| |
abrasion-resistant |
| Special properties |
Flexible cable conduit capable |
| |
Silicone-free |
| |
Free of substances which would hinder coating with paint or varnish |
| |
flexible |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PUR halogen-free yellow [240] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 / 10493 (80°C/300 V) |
| Cable weight |
35 kg/km |
| Cable type |
PUR halogen-free yellow |
| Short symbol |
Li9Y11Y |
| Cable type (abbreviation) |
240 |
| External cable diameter |
5 mm ±0.15 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
yellow |
| Thickness, outer sheath |
approx. 0.7 mm |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
5x 0.34 mm² |
| Material wire insulation |
PP |
| Thickness, insulation |
≥ 0.21 mm |
| Wire diameter incl. insulation |
1.27 mm ±0.02 mm |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Overall twist |
5 wires around filler to the core |
| Length of twist, overall twist |
55 mm |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
≤ 58 Ω/km (at 20 °C) |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
4000000 |
| Minimum bending radius, drag chain applications |
10 x D |
| Traversing path |
10 m |
| Traversing rate |
3 m/s |
| Acceleration |
10 m/s² |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with DIN UL-Style 20549 |
| |
in accordance with UL 758/1581 FT2 |
| Other resistance |
hydrolysis and microbe resistant |
| |
Resistant to salt water |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PUR irradiated halogen-free orange [150] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable type |
PUR irradiated halogen-free orange |
| Short symbol |
D12YSL11X-JB |
| Cable type (abbreviation) |
150 |
| External cable diameter |
5.2 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
orange RAL 2003 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor structure, voltage supply |
24x 0.15 mm |
| Conductor cross section |
4x 0.34 mm² (Signal line) |
| AWG power supply |
20 |
| Material wire insulation |
PE |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Overall twist |
5 cores, twisted |
| Nominal voltage, cable |
250 V (AC) |
| Test voltage, cable |
2000 V (50 Hz, 5 minutes) |
| Cable resistance |
≤ 57.5 Ω/km (with 0.34 mm² conductor cross section) |
| |
≤ 39 Ω/km (with 0.5 mm² conductor cross section) |
| Smallest bending radius, fixed installation |
min. 20 mm |
| Smallest bending radius, movable installation |
min. 30 mm |
| Number of bending cycles |
5000000 |
| Bending radius |
52 mm |
| Traversing path |
10 m |
| Traversing rate |
3 m/s |
| Halogen-free |
The cable is halogen-free |
| Flame resistance |
DIN VDE 0472 part 804, test type B |
| Other resistance |
hydrolysis and microbe resistant |
| |
UV resistant |
| |
Resistant to welding splashes |
| Special properties |
Silicone-free |
| |
Irradiated |
| Ambient temperature (operation) |
-40 °C ... 105 °C (Cable, flexible installation) |
| |
-50 °C ... 105 °C (cable, fixed installation) |
| PUR halogen-free orange [180] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
36 kg/km |
| Cable type |
PUR halogen-free orange |
| Short symbol |
Li9YLi9Y-11Y |
| Cable type (abbreviation) |
180 |
| External cable diameter |
5 mm ±0.15 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
orange RAL 2003 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor structure, voltage supply |
28x 0.15 mm |
| Conductor cross section |
4x 0.34 mm² (Signal line) |
| AWG power supply |
20 |
| Material wire insulation |
PP |
| Thickness, insulation |
≥ 0.21 mm (Signal line) |
| Wire diameter incl. insulation |
1.27 mm ±0.02 mm (Signal line) |
| |
1.46 mm ±0.02 mm (PE connection) |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Overall twist |
5 wires around filler to the core |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
≤ 58 Ω/km (Signal line) |
| |
≤ 39 Ω/km (PE connection) |
| Cable insulation resistance |
≥ 10 GΩ*km (at 20 °C) |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Flame resistance |
in accordance with DIN UL-Style 20549 |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable) |
| PUR POWER 0.75 mm² black [186] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable weight |
67 kg/km |
| Cable type |
PUR POWER 0.75 mm² black |
| Short symbol |
LiY11Y |
| Cable type (abbreviation) |
186 |
| External cable diameter |
6.3 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
black-gray RAL 7021 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.15 mm |
| AWG signal line |
18 |
| Conductor cross section |
5x 0.75 mm² (power line) |
| Material wire insulation |
PVC |
| Thickness, insulation |
≥ 0.23 mm (Core insulation) |
| Wire diameter incl. insulation |
1.7 mm ±0.05 mm |
| Single wire, color |
brown, white, blue, black, gray |
| Overall twist |
5 wires around filler to the core |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
max. 26 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 1 MΩ*km (at 20 °C) |
| Smallest bending radius, movable installation |
63 mm |
| Number of bending cycles |
2000000 |
| Bending radius |
63 mm |
| Traversing path |
5 m |
| Traversing rate |
3 m/s |
| Acceleration |
5 m/s² |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with DIN UL-Style 20549 |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-25 °C ... 80 °C (cable, fixed installation) |
| PUR halogen-free gray [280] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable type |
PUR halogen-free gray |
| Cable type (abbreviation) |
280 |
| External cable diameter |
5.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
gray RAL 7001 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor structure, voltage supply |
28x 0.15 mm |
| Conductor cross section |
0.34 mm² |
| AWG power supply |
20 |
| Material, filler |
Fiberglass |
| Material wire insulation |
TPE |
| Thickness, insulation |
0.39 mm (Signal line) |
| Wire diameter incl. insulation |
1.55 mm (Signal line) |
| |
1.65 mm (Protective conductor) |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Overall twist |
5 wires around filler to the core |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC gray [500] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
2464 / 1729 (80°C/300 V) |
| Cable weight |
51 kg/km |
| Cable type |
PVC gray |
| Short symbol |
LiYY |
| Cable type (abbreviation) |
500 |
| External cable diameter |
5 mm ±0.15 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
gray RAL 7001 |
| Thickness, outer sheath |
≥ 0.76 mm |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
19x 0.15 mm |
| AWG signal line |
22 |
| Conductor cross section |
5x 0.34 mm² (Signal line) |
| Material wire insulation |
PVC |
| Thickness, insulation |
≥ 0.23 mm (Core insulation) |
| Wire diameter incl. insulation |
1.26 mm ±0.05 mm |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Overall twist |
5 wires around filler to the core |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
max. 57 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 200 MΩ*km (at 20 °C) |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Flame resistance |
As per UL-Style 2464 |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC black 5th conductor gray [515] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
2464 / 1729 (80°C/300 V) |
| Cable weight |
52 kg/km |
| Cable type |
PVC black 5th conductor gray |
| Short symbol |
LiYY |
| Cable type (abbreviation) |
515 |
| External cable diameter |
5.9 mm ±0.15 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
black RAL 9005 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
5x 0.34 mm² (Signal line) |
| Material, filler |
PP yarn |
| Material wire insulation |
PVC |
| Thickness, insulation |
≥ 0.23 mm (Core insulation) |
| Wire diameter incl. insulation |
1.45 mm ±0.02 mm |
| Single wire, color |
brown, white, blue, black, gray |
| Overall twist |
5 wires around filler to the core |
| Length of twist, overall twist |
60 mm |
| Nominal voltage, cable |
≤ 300 V AC |
| Test voltage, cable |
≥ 3000 V AC |
| Cable resistance |
≤ 58 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 100 MΩ*km (at 20 °C) |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Resistance to oil |
according to DIN EN 60811-2-1, 168 h at 60 °C |
| Flame resistance |
According to UL 758/1581 (Cable Flame) |
| |
according to UL 758/1581 FT1 |
| |
According to DIN EN 60332-1-2 (60 s) |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC gray 5th conductor gray [520] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable weight |
54 kg/km |
| Cable type |
PVC gray 5th conductor gray |
| Short symbol |
LiYY |
| Cable type (abbreviation) |
520 |
| External cable diameter |
5.9 mm ±0.15 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
gray RAL 7001 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
0.34 mm² |
| Material, filler |
PVC |
| Material wire insulation |
PVC |
| Thickness, insulation |
≥ 0.23 mm (Core insulation) |
| Wire diameter incl. insulation |
1.45 mm ±0.02 mm |
| Single wire, color |
brown, white, blue, black, gray |
| Overall twist |
5 wires around filler to the core |
| Length of twist, overall twist |
55 mm |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
max. 58 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 1 GΩ*km (at 20 °C) |
| Flame resistance |
As per UL-Style 2464 |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-25 °C ... 80 °C (cable, fixed installation) |
| PVC yellow [540] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable type |
PVC yellow |
| Short symbol |
LiFYY |
| Cable type (abbreviation) |
540 |
| External cable diameter |
5.9 mm ±0.15 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
yellow |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
43x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
0.34 mm² |
| Material, filler |
PVC |
| Material wire insulation |
PVC |
| Thickness, insulation |
approx. 0.23 mm (Core insulation) |
| Wire diameter incl. insulation |
1.45 mm ±0.02 mm |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Overall twist |
5 wires around filler to the core |
| Length of twist, overall twist |
70 mm |
| Nominal voltage, cable |
≤ 300 V (AC) |
| Test voltage, cable |
3000 V |
| Cable resistance |
max. 58 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 1 MΩ*km (at 20 °C) |
| Smallest bending radius, fixed installation |
29.5 mm |
| Smallest bending radius, movable installation |
59 mm |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
As per UL-Style 2464 |
| |
according to UL 758/1581 FT1 |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC yellow 105 °C [542] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable weight |
50 kg/km |
| Cable type |
PVC yellow 105 °C |
| Cable type (abbreviation) |
542 |
| External cable diameter |
5.9 mm ±0.2 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
yellow |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
0.34 mm² |
| Material wire insulation |
PVC |
| Thickness, insulation |
≥ 0.38 mm (Core insulation) |
| Wire diameter incl. insulation |
1.55 mm ±0.05 mm |
| Single wire, color |
brown, white, blue, black, gray |
| Overall twist |
5 wires around filler to the core |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
max. 58 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 100 MΩ*km (at 20 °C) |
| Flame resistance |
in accordance with UL-Style 2517 |
| Gray, highly flexible PUR [800] |
| Dimensional drawing |
|
| Note |
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments. |
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
38 kg/km |
| Cable type |
Gray, highly flexible PUR |
| Short symbol |
LiF9Y11Y |
| Cable type (abbreviation) |
800 |
| External cable diameter |
5.1 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
gray RAL 7001 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
5x 0.34 mm² (Signal line) |
| Material, filler |
PE |
| Material wire insulation |
PP |
| Wire diameter incl. insulation |
1.3 mm ±0.05 mm (Signal line) |
| Single wire, color |
black, brown,blue, white, gray |
| Overall twist |
5 wires around filler to the core |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
2000 V |
| Cable resistance |
approx. 53 Ω/km |
| Cable insulation resistance |
≥ 20 MΩ*km |
| Minimum bending radius, fixed installation |
4 x D |
| Minimum bending radius, flexible installation |
7.5 x D |
| Number of bending cycles |
10000000 |
| Minimum bending radius, drag chain applications |
7,5 x D |
| Traversing path |
5 m |
| Traversing rate |
3.3 m/s |
| Acceleration |
5 m/s² |
| Number of bending cycles |
15000000 |
| Traversing path |
0.9 m |
| Traversing rate |
5 m/s |
| Acceleration |
30 m/s² |
| Torsion force |
± 360 °/m |
| Torsion cycles |
1000000 |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with UL 758/1581 FT2 |
| Other resistance |
Highly resistant to acids, alkaline solutions and solvents |
| |
Silicone-free |
| Special properties |
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing |
| |
Free from silicone and cadmium |
| |
Free of substances which would hinder coating with paint or varnish |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PUR halogen-free black [PUR] |
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
33 kg/km |
| Cable type |
PUR halogen-free black |
| Cable type (abbreviation) |
PUR |
| External cable diameter |
4.55 mm ±0.15 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
black-gray RAL 7021 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
42x 0.10 mm |
| AWG signal line |
22 |
| Conductor cross section |
5x 0.34 mm² (Signal line) |
| Material wire insulation |
PP |
| Thickness, insulation |
approx. 0.5 mm |
| Wire diameter incl. insulation |
1.27 mm 0.05 mm (Signal line) |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
3000 V |
| Cable resistance |
max. 58 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 16 GΩ*km (at 20 °C) |
| Smallest bending radius, fixed installation |
23 mm |
| Smallest bending radius, movable installation |
46 mm |
| Number of bending cycles |
4000000 |
| Bending radius |
50 mm |
| Traversing path |
10 m |
| Traversing rate |
3 m/s |
| Acceleration |
10 m/s² |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with UL 758/1581 FT2 |
| |
DIN EN 60332-2-2 (20 s) |
| Other resistance |
Highly resistant to acids, alkaline solutions and solvents |
| |
hydrolysis and microbe resistant |
| |
Resistant to salt water |
| |
partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
| Special properties |
Flexible cable conduit capable |
| |
Silicone-free |
| |
Free of substances which would hinder coating with paint or varnish |
| |
flexible |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC black [PVC] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
2464 / 1729 (80°C/300 V) |
| Cable weight |
51 kg/km |
| Cable type |
PVC black |
| Short symbol |
LiYY |
| Cable type (abbreviation) |
PVC |
| External cable diameter |
5 mm ±0.15 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
black RAL 9005 |
| Thickness, outer sheath |
≥ 0.76 mm |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
19x 0.15 mm |
| AWG signal line |
22 |
| Conductor cross section |
5x 0.34 mm² (Signal line) |
| Material wire insulation |
PVC |
| Thickness, insulation |
≥ 0.23 mm (Core insulation) |
| Wire diameter incl. insulation |
1.26 mm ±0.05 mm |
| Single wire, color |
brown, white, blue, black, green-yellow |
| Overall twist |
5 wires around filler to the core |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
max. 57 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 200 MΩ*km (at 20 °C) |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
As per UL-Style 2464 |
| Ambient temperature (operation) |
-10 °C ... 80 °C (Cable, flexible installation) |
| |
-25 °C ... 80 °C (cable, fixed installation) |