Cable length |
Free input (0.2 ... 40.0 m) |
PUR halogen-free black [PUR] |
Dimensional drawing |
|
Shielded |
no |
UL AWM Style |
20549 |
Cable weight |
23 kg/km |
Cable type |
PUR halogen-free black |
Short symbol |
Li9Y11Y |
Cable type (abbreviation) |
PUR |
External cable diameter |
3.85 mm ±0.15 mm |
Outer sheath, material |
PUR |
External sheath, color |
black-gray RAL 7021 |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
3x 0.34 mm² (Signal line) |
Material wire insulation |
PP |
Thickness, insulation |
≥ 0.21 mm (Core insulation) |
Wire diameter incl. insulation |
1.27 mm ±0.02 mm (Signal line) |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
≤ 300 V |
Test voltage, cable |
≥ 3000 V |
Cable resistance |
max. 58 Ω/km (at 20 °C) |
Cable insulation resistance |
≥ 100 GΩ*km (at 20 °C) |
Smallest bending radius, fixed installation |
19 mm |
Smallest bending radius, movable installation |
38 mm |
Number of bending cycles |
10000000 |
Bending radius |
38 mm |
Traversing path |
10 m |
Traversing rate |
3 m/s |
Acceleration |
10 m/s² |
Halogen-free |
in accordance with DIN VDE 0472 part 815 |
Resistance to oil |
in accordance with DIN EN 60811-2-1 |
Flame resistance |
in accordance with UL 758/1581 FT2 |
|
DIN EN 60332-2-2 (20 s) |
Other resistance |
Highly resistant to acids, alkaline solutions and solvents |
|
hydrolysis and microbe resistant |
|
partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
Special properties |
Flexible cable conduit capable |
|
Silicone-free |
|
Free of substances which would hinder coating with paint or varnish |
Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
|
-40 °C ... 80 °C (cable, fixed installation) |
PVC black [PVC] |
Dimensional drawing |
|
Shielded |
no |
UL AWM Style |
2464 / 1729 (80°C/300 V) |
Cable weight |
40 kg/km |
Cable type |
PVC black |
Short symbol |
LiYY |
Cable type (abbreviation) |
PVC |
External cable diameter |
5.2 mm ±0.2 mm |
Outer sheath, material |
PVC |
External sheath, color |
black RAL 9005 |
Thickness, outer sheath |
≥ 0.76 mm |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
3x 0.34 mm² (Signal line) |
Material wire insulation |
PVC |
Thickness, insulation |
≥ 0.23 mm (Core insulation) |
Wire diameter incl. insulation |
1.45 mm ±0.02 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
≤ 300 V |
Test voltage, cable |
≥ 2500 V |
Cable resistance |
max. 58 Ω/km (at 20 °C) |
Cable insulation resistance |
≥ 100 MΩ*km (at 20 °C) |
Minimum bending radius, fixed installation |
5 x D |
Minimum bending radius, flexible installation |
10 x D |
Resistance to oil |
according to DIN EN 60811-2-1, 168 h at 90 °C |
Flame resistance |
As per UL-Style 2464 |
Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
|
-40 °C ... 80 °C (cable, fixed installation) |
PUR halogen-free gray [280] |
Dimensional drawing |
|
Shielded |
no |
UL AWM Style |
20549 / 10493 (80°C/300 V) |
Cable weight |
23.42 kg/km |
Cable type |
PUR halogen-free gray |
Short symbol |
Li9Y-11Y |
Cable type (abbreviation) |
280 |
External cable diameter |
3.95 mm ±0.15 mm |
Outer sheath, material |
PUR |
External sheath, color |
gray RAL 7001 |
Thickness, outer sheath |
approx. 0.4 mm |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
3x 0.34 mm² (Signal line) |
Material wire insulation |
PP |
Thickness, insulation |
≥ 0.203 mm |
Wire diameter incl. insulation |
1.27 mm ±0.05 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
≤ 300 V |
Test voltage, cable |
≥ 3000 V |
Cable resistance |
≤ 58 Ω/km |
Cable insulation resistance |
≥ 20 MΩ*km |
Minimum bending radius, fixed installation |
5 x D |
Minimum bending radius, flexible installation |
10 x D |
Number of bending cycles |
10000000 |
Minimum bending radius, drag chain applications |
10 x D |
Traversing path |
10 m |
Traversing rate |
3 m/s |
Acceleration |
10 m/s² |
Halogen-free |
in accordance with DIN VDE 0472 part 815 |
|
EN 50267-2-1 |
Resistance to oil |
in accordance with DIN EN 60811-2-1 |
Flame resistance |
in accordance with UL 758/1581 FT2 |
|
DIN EN 60332-2-2 (20 s) |
Other resistance |
Highly resistant to acids, alkaline solutions and solvents |
|
hydrolysis and microbe resistant |
|
partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
|
Low adhesion |
|
abrasion-resistant |
Special properties |
Flexible cable conduit capable |
|
Silicone-free |
|
Free of substances which would hinder coating with paint or varnish |
|
flexible |
Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
|
-40 °C ... 80 °C (cable, fixed installation) |
PUR/PVC orange [110] |
Dimensional drawing |
|
Shielded |
no |
Cable weight |
37 kg/km |
Cable type |
PUR/PVC orange |
Short symbol |
LiYY-11Y |
Cable type (abbreviation) |
110 |
External cable diameter |
5.2 mm |
Outer sheath, material |
PUR |
External sheath, color |
orange RAL 2003 |
Material, inner sheath |
PVC |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
0.34 mm² |
Material wire insulation |
PVC |
Thickness, insulation |
≥ 0.23 mm (Core insulation) |
Wire diameter incl. insulation |
1.52 mm ±0.02 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
300 V |
Test voltage, cable |
2500 V |
Cable resistance |
max. 57.3 Ω/km |
Cable insulation resistance |
≥ 100 MΩ*km |
Smallest bending radius, fixed installation |
52 mm |
Smallest bending radius, movable installation |
52 mm |
Number of bending cycles |
2000000 |
Bending radius |
52 mm |
Traversing path |
5 m |
Traversing rate |
3 m/s |
Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
|
-25 °C ... 80 °C (cable, fixed installation) |
PUR/PVC yellow [140] |
Dimensional drawing |
|
Shielded |
no |
Cable weight |
37 kg/km |
Cable type |
PUR/PVC yellow |
Short symbol |
LiYY-11Y |
Cable type (abbreviation) |
140 |
External cable diameter |
5.2 mm ±0.2 mm |
Outer sheath, material |
PUR |
External sheath, color |
yellow |
Material, inner sheath |
PVC |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
0.34 mm² |
Material wire insulation |
PVC |
Thickness, insulation |
≥ 0.23 mm (Core insulation) |
Wire diameter incl. insulation |
1.52 mm ±0.02 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
300 V |
Test voltage, cable |
2500 V |
Cable resistance |
max. 57.3 Ω/km (at 20 °C) |
Cable insulation resistance |
≥ 100 MΩ*km (at 20 °C) |
Smallest bending radius, fixed installation |
52 mm |
Smallest bending radius, movable installation |
52 mm |
Number of bending cycles |
2000000 |
Bending radius |
52 mm |
Traversing path |
5 m |
Traversing rate |
3 m/s |
Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
|
-25 °C ... 80 °C (cable, fixed installation) |
PUR irradiated halogen-free orange [150] |
Dimensional drawing |
|
Shielded |
no |
Cable type |
PUR irradiated halogen-free orange |
Short symbol |
D12YSL11X-OB |
Cable type (abbreviation) |
150 |
External cable diameter |
4.4 mm ±0.2 mm |
Outer sheath, material |
PUR |
External sheath, color |
orange RAL 2003 |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
3x 0.34 mm² (Signal line) |
Material wire insulation |
PE |
Wire diameter incl. insulation |
1.05 mm ±0.05 mm (Signal line) |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
250 V (AC) |
Test voltage, cable |
2000 V (50 Hz, 5 minutes) |
Cable resistance |
max. 57 Ω/km |
Smallest bending radius, fixed installation |
13.5 mm |
Smallest bending radius, movable installation |
53 mm |
Number of bending cycles |
5000000 |
Bending radius |
44 mm |
Traversing path |
10 m |
Traversing rate |
3 m/s |
Acceleration |
10 m/s² |
Flame resistance |
according to DIN VDE 0472 Part 804 |
Other resistance |
UV resistant |
Special properties |
Silicone-free |
|
Irradiated |
Ambient temperature (operation) |
-40 °C ... 105 °C (Cable, flexible installation) |
|
-50 °C ... 105 °C (cable, fixed installation) |
PUR halogen-free gray [280] |
Dimensional drawing |
|
Shielded |
no |
UL AWM Style |
20549 / 10493 (80°C/300 V) |
Cable weight |
23.42 kg/km |
Cable type |
PUR halogen-free gray |
Short symbol |
Li9Y-11Y |
Cable type (abbreviation) |
280 |
External cable diameter |
3.95 mm ±0.15 mm |
Outer sheath, material |
PUR |
External sheath, color |
gray RAL 7001 |
Thickness, outer sheath |
approx. 0.4 mm |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
3x 0.34 mm² (Signal line) |
Material wire insulation |
PP |
Thickness, insulation |
≥ 0.203 mm |
Wire diameter incl. insulation |
1.27 mm ±0.05 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
≤ 300 V |
Test voltage, cable |
≥ 3000 V |
Cable resistance |
≤ 58 Ω/km |
Cable insulation resistance |
≥ 20 MΩ*km |
Minimum bending radius, fixed installation |
5 x D |
Minimum bending radius, flexible installation |
10 x D |
Number of bending cycles |
10000000 |
Minimum bending radius, drag chain applications |
10 x D |
Traversing path |
10 m |
Traversing rate |
3 m/s |
Acceleration |
10 m/s² |
Halogen-free |
in accordance with DIN VDE 0472 part 815 |
|
EN 50267-2-1 |
Resistance to oil |
in accordance with DIN EN 60811-2-1 |
Flame resistance |
in accordance with UL 758/1581 FT2 |
|
DIN EN 60332-2-2 (20 s) |
Other resistance |
Highly resistant to acids, alkaline solutions and solvents |
|
hydrolysis and microbe resistant |
|
partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
|
Low adhesion |
|
abrasion-resistant |
Special properties |
Flexible cable conduit capable |
|
Silicone-free |
|
Free of substances which would hinder coating with paint or varnish |
|
flexible |
Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
|
-40 °C ... 80 °C (cable, fixed installation) |
PVC gray [500] |
Dimensional drawing |
|
Shielded |
no |
Cable weight |
40 kg/km |
Cable type |
PVC gray |
Short symbol |
LiYY |
Cable type (abbreviation) |
500 |
External cable diameter |
5.2 mm ±0.2 mm |
Outer sheath, material |
PVC |
External sheath, color |
gray RAL 7001 |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
0.34 mm² |
Material wire insulation |
PVC |
Thickness, insulation |
≥ 0.23 mm (Core insulation) |
Wire diameter incl. insulation |
1.45 mm ±0.02 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
≤ 300 V |
Test voltage, cable |
≥ 3000 V |
Cable resistance |
max. 58 Ω/km (at 20 °C) |
Cable insulation resistance |
≥ 1 GΩ*km (at 20 °C) |
Flame resistance |
As per UL-Style 2464 |
Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
|
-25 °C ... 80 °C (cable, fixed installation) |
PVC yellow [540] |
Dimensional drawing |
|
Shielded |
no |
Cable weight |
40 kg/km |
Cable type |
PVC yellow |
Short symbol |
LiYY |
Cable type (abbreviation) |
540 |
External cable diameter |
5.2 mm ±0.2 mm |
Outer sheath, material |
PVC |
External sheath, color |
yellow |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
0.34 mm² |
Material wire insulation |
PVC |
Thickness, insulation |
≥ 0.23 mm (Core insulation) |
Wire diameter incl. insulation |
1.45 mm ±0.05 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
≤ 300 V |
Test voltage, cable |
≥ 3000 V |
Cable resistance |
max. 58 Ω/km (at 20 °C) |
Cable insulation resistance |
≥ 1 GΩ*km (at 20 °C) |
Flame resistance |
As per UL-Style 2464 |
Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
|
-25 °C ... 80 °C (cable, fixed installation) |
PVC yellow 105 °C [542] |
Dimensional drawing |
|
Shielded |
no |
Cable weight |
38 kg/km |
Cable type |
PVC yellow 105 °C |
Cable type (abbreviation) |
542 |
External cable diameter |
5.2 mm ±0.2 mm |
Outer sheath, material |
PVC |
External sheath, color |
yellow |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
0.34 mm² |
Material wire insulation |
PVC |
Thickness, insulation |
≥ 0.38 mm (Core insulation) |
Wire diameter incl. insulation |
1.55 mm ±0.05 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
300 V |
Test voltage, cable |
4000 V |
Cable resistance |
max. 58 Ω/km (at 20 °C) |
Cable insulation resistance |
≥ 100 MΩ*km (at 20 °C) |
Flame resistance |
according to DIN 50265-2-1 |
Gray, highly flexible PUR [800] |
Dimensional drawing |
|
Note |
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments. |
Shielded |
no |
UL AWM Style |
20549 |
Cable weight |
28.3 kg/km |
Cable type |
Gray, highly flexible PUR |
Short symbol |
LiF9Y11Y |
Cable type (abbreviation) |
800 |
External cable diameter |
4.5 mm ±0.2 mm |
Outer sheath, material |
PUR |
External sheath, color |
gray RAL 7001 |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
42x 0.10 mm |
AWG signal line |
22 |
Conductor cross section |
3x 0.34 mm² (Signal line) |
Material wire insulation |
PP |
Wire diameter incl. insulation |
1.3 mm ±0.05 mm (Signal line) |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Nominal voltage, cable |
300 V |
Test voltage, cable |
2000 V |
Cable resistance |
approx. 53 Ω/km |
Cable insulation resistance |
≥ 20 MΩ*km |
Minimum bending radius, fixed installation |
4 x D |
Minimum bending radius, flexible installation |
7.5 x D |
Number of bending cycles |
10000000 |
Minimum bending radius, drag chain applications |
7,5 x D |
Traversing path |
5 m |
Traversing rate |
3.3 m/s |
Acceleration |
5 m/s² |
Number of bending cycles |
15000000 |
Traversing path |
0.9 m |
Traversing rate |
5 m/s |
Acceleration |
30 m/s² |
Torsion force |
± 360 °/m |
Torsion cycles |
1000000 |
Halogen-free |
in accordance with DIN VDE 0472 part 815 |
Resistance to oil |
in accordance with DIN EN 60811-2-1 |
Flame resistance |
in accordance with UL 758/1581 FT2 |
Other resistance |
Highly resistant to acids, alkaline solutions and solvents |
|
Silicone-free |
Special properties |
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing |
|
Free from silicone and cadmium |
|
Free of substances which would hinder coating with paint or varnish |
Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
|
-40 °C ... 80 °C (cable, fixed installation) |
PUR halogen-free black [PUR] |
Dimensional drawing |
|
Shielded |
no |
UL AWM Style |
20549 / 10493 (80°C/300 V) |
Cable weight |
18 kg/km |
Cable type |
PUR halogen-free black |
Short symbol |
Li9Y11Y-HF |
Cable type (abbreviation) |
PUR |
External cable diameter |
3.6 mm ±0.15 mm |
Outer sheath, material |
PUR |
External sheath, color |
black-gray RAL 7021 |
Thickness, outer sheath |
approx. 0.5 mm |
Conductor material |
Bare Cu litz wires |
Conductor structure signal line |
32x 0.10 mm |
AWG signal line |
24 |
Conductor cross section |
3x 0.25 mm² (Signal line) |
Material wire insulation |
PP |
Thickness, insulation |
≥ 0.21 mm (Core insulation) |
Wire diameter incl. insulation |
1.17 mm ±0.02 mm |
Single wire, color |
brown, blue, black |
Overall twist |
3 wires, twisted |
Length of twist, overall twist |
40 mm |
Nominal voltage, cable |
≤ 300 V |
Test voltage, cable |
≥ 3000 V |
Cable resistance |
≤ 78 Ω/km (at 20 °C) |
Cable insulation resistance |
≥ 100 GΩ*km (at 20 °C) |
Smallest bending radius, fixed installation |
18 mm |
Smallest bending radius, movable installation |
36 mm |
Number of bending cycles |
10000000 |
Bending radius |
44 mm |
Traversing path |
10 m |
Traversing rate |
3 m/s |
Acceleration |
10 m/s² |
Halogen-free |
in accordance with DIN VDE 0472 part 815 |
Resistance to oil |
in accordance with DIN EN 60811-2-1 |
Flame resistance |
in accordance with UL 758/1581 FT2 |
|
DIN EN 60332-2-2 (20 s) |
Other resistance |
hydrolysis and microbe resistant |
|
Highly resistant to acids, alkaline solutions and solvents |
|
Resistant to salt water |
|
partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
Special properties |
Flexible cable conduit capable |
|
Silicone-free |
|
Free of substances which would hinder coating with paint or varnish |
Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
|
-40 °C ... 80 °C (cable, fixed installation) |