| Cable length |
Free input (0.2 ... 40.0 m) |
| PUR/PVC, 0.75 mm², black [116] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
53.4 kg/km |
| Cable type |
PUR/PVC, 0.75 mm², black |
| Short symbol |
LiYY11Y |
| Cable type (abbreviation) |
116 |
| External cable diameter |
5.8 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
black RAL 9005 |
| Material, inner sheath |
PVC |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
24x 0.20 mm |
| AWG signal line |
18 |
| Conductor cross section |
3x 0.75 mm² |
| Material wire insulation |
PVC |
| Wire diameter incl. insulation |
1.7 mm ±0.05 mm |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
3 wires, twisted |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
1200 V |
| Cable resistance |
26 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 20 MΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
1000000 |
| Traversing path |
10 m |
| Traversing rate |
2 m/s |
| Acceleration |
2.5 m/s² |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
DIN VDE 0482 |
| |
DIN EN 50265-2-1 |
| |
in acc. with UL FT-2 |
| Other resistance |
Low adhesion |
| Special properties |
flexible |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PUR/PVC 0.75 mm² gray [117] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
58.5 kg/km |
| Cable type |
PUR/PVC 0.75 mm² gray |
| Short symbol |
LiYY11Y |
| Cable type (abbreviation) |
117 |
| External cable diameter |
5.8 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
gray RAL 7001 |
| Material, inner sheath |
PVC |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
24x 0.20 mm |
| AWG signal line |
18 |
| Conductor cross section |
3x 0.75 mm² (Signal line) |
| Material wire insulation |
PVC |
| Wire diameter incl. insulation |
1.7 mm ±0.05 mm (Signal line) |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
Wires twisted in layers |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
1200 V |
| Cable resistance |
26 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 20 MΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
1000000 |
| Traversing rate |
2 m/s |
| Acceleration |
2.5 m/s² |
| Flame resistance |
according to DIN VDE 0482 |
| |
According to DIN EN 50265-2-1 |
| |
in acc. with UL FT-2 |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PUR irradiated halogen-free orange [150] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable weight |
31 kg/km |
| Cable type |
PUR irradiated halogen-free orange |
| Short symbol |
Li12Y11X |
| Cable type (abbreviation) |
150 |
| External cable diameter |
4.5 mm ±0.15 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
orange RAL 2003 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
28x 0.15 mm |
| AWG signal line |
20 |
| Conductor cross section |
3x 0.5 mm² (Signal line) |
| Material wire insulation |
TPE-E |
| Thickness, insulation |
≥ 0.21 mm (Core insulation) |
| Wire diameter incl. insulation |
1.46 mm ±0.02 mm (Signal line) |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
3 wires, twisted |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
max. 39 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 100 MΩ*km (at 20 °C) |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
5000000 |
| Bending radius |
45 mm |
| Traversing path |
10 m |
| Traversing rate |
3 m/s |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with DIN UL-Style 20549 |
| Special properties |
Silicone-free |
| |
Irradiated |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-25 °C ... 80 °C (cable, fixed installation) |
| PUR halogen-free yellow [240] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 (80°C/300 V) |
| Cable weight |
30 kg/km |
| Cable type |
PUR halogen-free yellow |
| Short symbol |
Li9Y11Y |
| Cable type (abbreviation) |
240 |
| External cable diameter |
4.5 mm ±0.15 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
yellow |
| Thickness, outer sheath |
approx. 0.6 mm |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
28x 0.15 mm |
| AWG signal line |
20 |
| Conductor cross section |
3x 0.5 mm² |
| Material wire insulation |
PP |
| Thickness, insulation |
≥ 0.21 mm |
| Wire diameter incl. insulation |
1.46 mm ±0.02 mm |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
3 wires, twisted |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 3000 V |
| Cable resistance |
≤ 39 Ω/km |
| Cable insulation resistance |
≥ 10 GΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with DIN UL-Style 20549 |
| Ambient temperature (operation) |
-15 °C ... 80 °C (cable, fixed installation) |
| PUR halogen-free gray [280] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
33.2 kg/km |
| Cable type |
PUR halogen-free gray |
| Short symbol |
Li9Y11Y-HF |
| Cable type (abbreviation) |
280 |
| External cable diameter |
4.5 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
gray RAL 7001 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
28x 0.15 mm |
| AWG signal line |
20 |
| Conductor cross section |
3x 0.5 mm² (Signal line) |
| Material wire insulation |
PP |
| Wire diameter incl. insulation |
1.5 mm ±0.05 mm (Signal line) |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
Wires twisted in layers |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
1200 V |
| Cable resistance |
39 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 20 MΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
15000000 |
| Bending radius |
50 mm |
| Traversing path |
0.9 m |
| Traversing rate |
5 m/s |
| Acceleration |
30 m/s² |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
according to DIN VDE 0482 |
| |
According to DIN EN 50265-2-1 |
| Ambient temperature (operation) |
-20 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC gray [500] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable weight |
39.2 kg/km |
| Cable type |
PVC gray |
| Short symbol |
LiYY |
| Cable type (abbreviation) |
500 |
| Cable type |
Round cable |
| External cable diameter |
4.8 mm ±0.2 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
gray RAL 7001 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
16x 0.20 mm |
| AWG signal line |
20 |
| Conductor cross section |
3x 0.5 mm² (Signal line) |
| Material wire insulation |
PVC |
| Wire diameter incl. insulation |
1.5 mm ±0.05 mm (Signal line) |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
Wires twisted in layers |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
1200 V |
| Cable resistance |
39 Ω/km (at 20 °C) |
| Cable insulation resistance |
min. 20 MΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
DIN EN 50265-2-1 |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC, 0.75 mm², black [534] |
| Dimensional drawing |
|
| Shielded |
no |
| Cable weight |
49.1 kg/km |
| Cable type |
PVC, 0.75 mm², black |
| Cable type (abbreviation) |
534 |
| External cable diameter |
5.3 mm ±0.2 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
black |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
24x 0.20 mm |
| AWG signal line |
18 |
| Conductor cross section |
3x 0.75 mm² |
| Material wire insulation |
PVC |
| Wire diameter incl. insulation |
1.7 mm ±0.1 mm |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
3 wires, twisted |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
1200 V |
| Cable resistance |
26 Ω/km (at 20 °C) |
| Cable insulation resistance |
min. 20 MΩ*km (at 20 °C) |
| Minimum bending radius, fixed installation |
5 x D |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
DIN VDE 0482 |
| |
DIN EN 50265-2-1 |
| |
in acc. to UL VW1 |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PUR, halogen-free, highly stranded, resistant to welding sparks, gray [800] |
| Dimensional drawing |
|
| Note |
Due to the extremely robust outer sheath, this cable should only be stripped in 5 cm increments. |
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
31 kg/km |
| Cable type |
PUR, halogen-free, highly stranded, resistant to welding sparks, gray |
| Short symbol |
LiF9Y11Y |
| Cable type (abbreviation) |
800 |
| External cable diameter |
4.5 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
gray RAL 7001 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
28x 0.15 mm |
| AWG signal line |
20 |
| Conductor cross section |
3x 0.5 mm² (Signal line) |
| Material wire insulation |
PP |
| Wire diameter incl. insulation |
1.5 mm ±0.05 mm (Signal line) |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
Wires twisted in layers |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
1200 V |
| Cable resistance |
39 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 20 MΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
15000000 |
| Bending radius |
50 mm |
| Traversing path |
0.9 m |
| Traversing rate |
5 m/s |
| Acceleration |
30 m/s² |
| Torsion force |
± 360 °/m |
| Halogen-free |
The cable is halogen-free |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
in accordance with UL 758/1581 FT2 |
| Other resistance |
Highly resistant to acids, alkaline solutions and solvents |
| Special properties |
Cable jacket is welding spark-resistant, recyclable, matt, low-adhesion, abrasion-resistant, flame-retardant, and self-extinguishing |
| |
Free from silicone and cadmium |
| |
Free of substances which would hinder coating with paint or varnish |
| Ambient temperature (operation) |
-25 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PUR halogen-free black [PUR] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
20549 |
| Cable weight |
30 kg/km |
| Cable type |
PUR halogen-free black |
| Short symbol |
Li9Y11Y-HF |
| Cable type (abbreviation) |
PUR |
| External cable diameter |
4.5 mm ±0.2 mm |
| Outer sheath, material |
PUR |
| External sheath, color |
black-gray RAL 7021 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
28x 0.15 mm |
| AWG signal line |
20 |
| Conductor cross section |
3x 0.5 mm² |
| Material wire insulation |
PP |
| Wire diameter incl. insulation |
1.5 mm ±0.05 mm (Signal line) |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
3 wires, twisted |
| Nominal voltage, cable |
≤ 300 V |
| Test voltage, cable |
≥ 1200 V |
| Cable resistance |
39 Ω/km (at 20 °C) |
| Cable insulation resistance |
min. 20 MΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Minimum bending radius, flexible installation |
10 x D |
| Number of bending cycles |
15000000 |
| Bending radius |
50 mm |
| Traversing path |
0.9 m |
| Traversing rate |
5 m/s |
| Acceleration |
30 m/s² |
| Halogen-free |
in accordance with DIN VDE 0472 part 815 |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
according to DIN VDE 0482 |
| |
According to DIN EN 50265-2-1 |
| Other resistance |
largely oil-resistant |
| |
partly UV-resistant in accordance with DIN EN ISO 4892-2-A |
| Ambient temperature (operation) |
-20 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |
| PVC black [PVC] |
| Dimensional drawing |
|
| Shielded |
no |
| UL AWM Style |
2464 |
| Cable weight |
38.6 kg/km |
| Cable type |
PVC black |
| Short symbol |
LiYY |
| Cable type (abbreviation) |
PVC |
| External cable diameter |
4.8 mm ±0.2 mm |
| Outer sheath, material |
PVC |
| External sheath, color |
black RAL 9005 |
| Conductor material |
Bare Cu litz wires |
| Conductor structure signal line |
16x 0.20 mm |
| AWG signal line |
20 |
| Conductor cross section |
3x 0.5 mm² |
| Material wire insulation |
PVC |
| Wire diameter incl. insulation |
1.5 mm ±0.05 mm |
| Single wire, color |
black 1, black 2, green/yellow |
| Overall twist |
3 wires, twisted |
| Nominal voltage, cable |
300 V |
| Test voltage, cable |
1200 V |
| Cable resistance |
39 Ω/km (at 20 °C) |
| Cable insulation resistance |
≥ 20 MΩ*km |
| Minimum bending radius, fixed installation |
5 x D |
| Resistance to oil |
in accordance with DIN EN 60811-2-1 |
| Flame resistance |
DIN VDE 0482 |
| |
DIN EN 50265-2-1 |
| Ambient temperature (operation) |
-5 °C ... 80 °C (Cable, flexible installation) |
| |
-40 °C ... 80 °C (cable, fixed installation) |