Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (selective fuse breaking) technology, and NFC interface, input: 3-phase, output: 24 V DC/20 A

Liên hệ mua hàng

Hãng sản xuất: PHOENIX CONTACT

Chất lượng: Mới 100%

Bảo hành: Chính hãng

Chứng từ: CO/CQ, hóa đơn VAT

Liên hệ(SĐT/Zalo): 0933612627

Control input (configurable) Rem Output power ON/OFF (SLEEP MODE)
Default Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)
AC operation
Network type Star network
Nominal input voltage range 3x 400 V AC ... 500 V AC
2x 400 V AC ... 500 V AC
Input voltage range 3x 400 V AC ... 500 V AC -20 % ... +10 %
2x 400 V AC ... 500 V AC -10 % ... +10 %
Typical national grid voltage 400 V AC
480 V AC
Voltage type of supply voltage AC
Inrush current typ. 2 A (at 25 °C)
Inrush current integral (I2t) < 0.1 A2s
Inrush current limitation 2 A (after 1 ms)
AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
Frequency range (fN) 50 Hz ... 60 Hz -10 % ... +10 %
Mains buffering time typ. 33 ms (3x 400 V AC)
typ. 33 ms (3x 480 V AC)
Current consumption 3x 0.99 A (400 V AC)
3x 0.81 A (480 V AC)
2x 1.62 A (400 V AC)
2x 1.37 A (480 V AC)
3x 0.8 A (500 V AC)
2x 1.23 A (500 V AC)
Nominal power consumption 541 VA
Protective circuit Transient surge protection; Varistor, gas-filled surge arrester
Power factor (cos phi) 0.94
Switch-on time < 1 s
Typical response time 300 ms (from SLEEP MODE)
Recommended breaker for input protection 3x 4 A ... 20 A (Characteristic B, C or comparable)
Recommended fuse for input protection ≥ 300 V AC
Discharge current to PE < 3.5 mA
1.7 mA (550 V AC, 60 Hz)
DC operation
Nominal input voltage range ± 260 V DC ... 300 V DC
Input voltage range ± 260 V DC ... 300 V DC -13 % ... +30 %
Voltage type of supply voltage DC
Current consumption 1.23 A (± 260 V DC)
1.06 A (±300 V DC)
Recommended breaker for input protection 1x 6 A (10 x 38 mm, 30 kA L/R = 2 ms)
Recommended fuse for input protection ≥ 1000 V DC
Efficiency typ. 93.9 % (400 V AC)
typ. 93.8 % (480 V AC)
Output characteristic U/I Advanced
Smart HICCUP
FUSE MODE
Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (constant capacity)
Nominal output current (IN) 20 A
Static Boost (IStat.Boost) 25 A
Dynamic Boost (IDyn.Boost) 30 A (5 s)
Selective Fuse Breaking (ISFB) 120 A (15 ms)
Magnetic circuit breaker tripping A1...A16 / B2...B13 / C1...C6 / Z1...Z16
Derating > 60 °C ... 70 °C (2.5%/K)
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 32 V DC
Control deviation < 0.5 % (Static load change 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
< 0.25 % (change in input voltage ±10 %)
Residual ripple < 60 mVPP (with nominal values)
Short-circuit-proof yes
No-load proof yes
Output power 480 W
600 W
720 W
Apparent power 686 VA (400 V, UOUT = 24 V, IOUT = stat. Boost)
698 VA (480 V, UOUT = 24 V, IOUT = stat. Boost)
Maximum no-load power dissipation < 7 W (400 V AC)
< 7 W (480 V AC)
Power loss nominal load max. < 32 W (400 V AC)
< 33 W (480 V AC)
Power dissipation SLEEP MODE < 5 W (400 V AC)
< 5 W (480 V AC)
Crest factor typ. 1.78 (400 V AC)
typ. 2.1 (480 V AC)
Rise time < 80 ms (UOut = 10 % ... 90 %)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Signal
Signal ground SGnd Reference potential for Out1, Out2, and Rem
Signal Out 1 (configurable)
Digital 24 V DC 20 mA
Default 24 V DC 20 mA 24 V DC for UOut > 0.9 x USet
Signal Out 2 (configurable)
Digital 24 V DC 20 mA
Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
Default 24 V DC 20 mA 24 V DC for POut < PN
Signal relay 13/14 (configurable)
Default closed (Uout > 0.9 USet)
Digital 24 V DC 1 A
30 V AC/DC 0.5 A
Input
Connection method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 4 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 10
Stripping length 8 mm
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Output
Connection method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 6 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 4 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 4 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 10
Stripping length 8 mm
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Signal
Connection method Push-in connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 1 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm
Types of signaling LED
Floating signal contact
Active signal output Out1 (digital, configurable)
Active signal output Out2 (analog, configurable)
Remote contact
Signal ground SGnd
Signal output
POut > 100 % (LED lights up yellow, output power > 480 W)
> 75 % (LED lights up green, output power > 360 W)
> 50 % (LED lights up green, output power > 240 W)
UOut > 0.9 x USet (LED lights up green)
< 0.9 x USet (LED flashes green)
Number of phases 3.00
Insulation voltage input/output 4 kV AC (type test)
2.4 kV AC (routine test)
Insulation voltage output / PE 0.5 kV DC (type test)
0.5 kV DC (routine test)
Insulation voltage input / PE 3.5 kV AC (type test)
2.4 kV AC (routine test)
Switching frequency 90 kHz ... 110 kHz (Auxiliary converter stage)
56 kHz ... 500 kHz (Main converter stage)
25 kHz ... 500 kHz (PFC stage)
Product type Power supply
Product family QUINT POWER
MTBF (IEC 61709, SN 29500) > 985000 h (25 °C)
> 638000 h (40 °C)
> 311000 h (60 °C)
Environmental protection directive RoHS Directive 2011/65/EU
WEEE
Reach
Insulation characteristics
Protection class I
Degree of pollution 2
Life expectancy (electrolytic capacitors)
Current 10 A
Temperature 40 °C
Time 344000 h
Additional text 400 V AC
Life expectancy (electrolytic capacitors)
Current 10 A
Temperature 40 °C
Time 320000 h
Additional text 480 V AC
Life expectancy (electrolytic capacitors)
Current 20 A
Temperature 25 °C
Time 445000 h
Additional text 400 V AC
Life expectancy (electrolytic capacitors)
Current 20 A
Temperature 25 °C
Time 432000 h
Additional text 480 V AC
Life expectancy (electrolytic capacitors)
Current 20 A
Temperature 40 °C
Time 157000 h
Additional text 400 V AC
Life expectancy (electrolytic capacitors)
Current 20 A
Temperature 40 °C
Time 152000 h
Additional text 480 V AC
Dimensional drawing
Width 70 mm
Height 130 mm
Depth 125 mm
Installation dimensions
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
Alternative assembly
Width 122 mm
Height 130 mm
Depth 73 mm
Mounting type DIN rail mounting
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Mounting position horizontal DIN rail NS 35, EN 60715
With protective coating No
Flammability rating according to UL 94 (housing / terminal blocks) V0
Housing material Metal
Hood version Stainless steel X6Cr17
Side element version Aluminum
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Ambient temperature (start-up type tested) -40 °C
Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
Rail applications EN 50121-3-2
EN 50121-4
EN 50121-5
IEC 62236-3-2
IEC 62236-4
IEC 62236-5
HART FSK Physical Layer Test Specification Compliance Output voltage UOut compliant
Standard – Limitation of mains harmonic currents EN 61000-3-2
Standard - Electrical safety IEC 61010-2-201 (SELV)
Standard – Safety extra-low voltage IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation IEC 61558-2-16 pending
IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
Standard - Safety of transformers IEC 61558-2-16 pending
Standard - power supply devices for low voltage with DC output EN 61204-3
Battery charging DIN 41773-1
Approval - requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706, EN 61000-4-11
Overvoltage category
EN 61010-1 II (≤ 5000 m)
EN 62477-1 III (≤ 2000 m)
CSA CAN/CSA-C22.2 No. 60950-1-07
CSA-C22.2 No. 107.1-01
Shipbuilding approval DNV GL, PRS, BV, LR, ABS
SIQ BG (type approved)
UL approvals UL Listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
EMC requirements, power plant IEC 61850-3
EN 61000-6-5
Conducted noise emission EN 55016
EN 61000-6-3 (Class B)
Noise emission Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise emission EN 55016
EN 61000-6-3 (Class B)
DNV GL conducted interference Class A
Additional text Area power distribution
DNV GL noise radiation Class B
Additional text Bridge and deck area
Harmonic currents
Standards/regulations EN 61000-3-2
EN 61000-3-2 (Class A)
Frequency range 0 kHz ... 2 kHz
Flicker
Standards/regulations EN 61000-3-3
EN 61000-3-3
Frequency range 0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Comments Criterion A
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 1 GHz ... 6 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 1 GHz ... 6 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 4 kV (Test Level 4 - asymmetrical)
Output 4 kV (Test Level 4 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input 3 kV (Test Level 4 - symmetrical)
6 kV (Test Level 4 - asymmetrical)
Output 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion A
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)
Power frequency magnetic field
Standards/regulations EN 61000-4-8
Frequency 16.7 Hz
50 Hz
60 Hz
Test field strength 100 A/m
Additional text 60 s
Comments Criterion A
Frequency 50 Hz
60 Hz
Frequency range 50 Hz ... 60 Hz
Test field strength 1 kA/m
Additional text 3 s
Frequency 0 Hz
Test field strength 300 A/m
Additional text DC, 60 s
Voltage dips
Standards/regulations EN 61000-4-11
Voltage 400 V AC
Frequency 50 Hz
Voltage dip 70 %
Number of periods 0.5 / 1 / 25 periods
Additional text Test Level 2
Comments Criterion A: 0.5 / 1 period
Criterion B: 25 periods
Voltage dip 40 %
Number of periods 5 / 10 / 50 periods
Additional text Test Level 2
Comments Criterion B
Voltage dip 0 %
Number of periods 0,5 / 1 / 5 / 50 / 250 periods
Additional text Test Level 2
Comments Criterion A: 0.5 / 1 period
Criterion B: 5 / 50 / 250 periods
Pulse-shape magnetic field
Standards/regulations EN 61000-4-9
Test field strength 1000 A/m
Comments Criterion A
Attenuated sinusoidal oscillations (ring wave)
Standards/regulations EN 61000-4-12
Input 2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Asymmetrical conducted disturbance variables
Standards/regulations EN 61000-4-16
Test level 1 15 Hz 150 Hz (Test Level 4)
Voltage 30 V 3 V
Test level 2 150 Hz 1.5 kHz (Test Level 4)
Voltage 3 V
Test level 3 1.5 kHz 15 kHz (Test Level 4)
Voltage 3 V 30 V
Test level 4 15 kHz 150 kHz (Test Level 4)
Voltage 30 V
Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
Voltage 30 V (Permanent)
Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
Voltage 300 V (1 s)
Comments Criterion A
Attenuated oscillating wave
Standards/regulations EN 61000-4-18
Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
Voltage 1 kV
Input, output (test level 2) 10 MHz
Voltage 1 kV
Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
Voltage 2.5 kV
Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
Voltage 1 kV
Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
Voltage 2.5 kV
Comments Criterion A
Attenuated oscillating magnetic field
Standards/regulations EN 61000-4-10
Test field strength 110 A/m
Test level 1 100 kHz
Test field strength 110 A/m
Test level 2 1 MHz
Comments Criterion A
Criteria
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Sản phẩm thịnh hành

Máy nén Embraco NTX6238U 843JA72 2172W

Máy nén Embraco NTX6238U 843JA72 2172W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2446W

Máy nén Embraco NTX6238U 843JA72 2446W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2735W

Máy nén Embraco NTX6238U 843JA72 2735W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2841W

Máy nén Embraco NTX6238U 843JA72 2841W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 1868W

Máy nén Embraco NTX6233U 843FA72 1868W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2088W

Máy nén Embraco NTX6233U 843FA72 2088W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2348W

Máy nén Embraco NTX6233U 843FA72 2348W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2425W

Máy nén Embraco NTX6233U 843FA72 2425W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1702W

Máy nén Embraco NTX6225UV 843HD72 1702W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1978W

Máy nén Embraco NTX6225UV 843HD72 1978W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2161W

Máy nén Embraco NTX6225UV 843HD72 2161W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2236W

Máy nén Embraco NTX6225UV 843HD72 2236W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ: