Nominal input voltage range 24 V DC
Input voltage range 24 V DC -25 % ... +40 %
Wide-range input no
Electric strength, max. 35 V DC (60 s)
Inrush current typ. 2.7 A
Inrush current integral (I2t) < 0.2 A2s
Inrush current limitation 2.7 A (after 1 ms)
Mains buffering time typ. 16 ms (24 V DC)
Current consumption 27 A (24 V DC)
Typical response time 300 ms (from SLEEP MODE)
Switch-on time < 1 s
Recommended breaker for input protection 50 A (Characteristic B, C or comparable)
Signal Remote (configurable)
Connection labeling 3.3 +
Function Output power ON/OFF (remote)
Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
Efficiency typ. 94.7 % (24 V DC)
Output characteristic U/I Advanced
Smart HICCUP
FUSE MODE
Nominal output voltage 24 V DC
Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity)
Nominal output current (IN) 20 A
Static Boost (IStat.Boost) 25 A
Dynamic Boost (IDyn.Boost) 30 A (5 s)
Selective Fuse Breaking (ISFB) 120 A (15 ms)
Magnetic circuit breaker tripping A1...A16 / B2...B13 / C1...C6 / Z1...Z16
Short-circuit-proof yes
No-load proof yes
Output power (PN) 480 W
Output power (PStat. Boost) 600 W
Output power (PDyn. Boost) 720 W (5 s)
Feedback voltage resistance ≤ 35 V DC
Protection against overvoltage at the output (OVP) ≤ 30 V DC
Residual ripple < 50 mVPP
Control deviation < 3 % (change in load, static 10 % ... 90 %)
Control deviation < 3 % (change in load, static 10 % ... 90 %)
Control deviation < 3 % (change in load, static 10 % ... 90 %)
Rise time < 100 ms (UOUT (10 % ... 90 %))
Connection in series yes
Maximum no-load power dissipation < 4 W
Power loss nominal load max. < 26.6 W
Power dissipation SLEEP MODE < 2 W
Connection in parallel yes, for redundancy and increased capacity
Signal Out 1 (configurable)
Connection labeling 3.5 +
Digital 0 V DC
24 V DC
20 mA
Signal option Output voltage
Output current
Output power
Operating hours
Early warning of high temperatures
OVP voltage limitation active
Default UIN input voltage OK
Signal Out 2 (configurable)
Connection labeling 3.6 +
Digital 0 V DC
24 V DC
20 mA
Default Output power
Signal option Output voltage
Output current
Operating hours
Early warning of high temperatures
OVP voltage limitation active
Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
Signal option Output voltage
Output current
Output power
Signal relay 13/14 (configurable)
Connection labeling 3.1, 3.2
Switch contact (floating) floating
Maximum contact load 24 V DC
1 A
30 V AC
0.5 A
Default Output voltage
Signal option Output current
Output power
Operating hours
Early warning of high temperatures
OVP voltage limitation active
UIN input voltage OK
Signal ground SGnd
Connection labeling 3.4 +
Function Signal ground
Reference potential to OUT1, OUT2, REM
Input
Position 1.x
Conductor connection
Connection method Screw connection
rigid 0.75 mm² ... 16 mm²
flexible 0.75 mm² ... 16 mm²
flexible with ferrule without plastic sleeve 0.75 mm² ... 16 mm²
flexible with ferrule with plastic sleeve 0.75 mm² ... 16 mm²
rigid (AWG) 20 ... 6
Stripping length 18 mm
Tightening torque 1.4 Nm ... 1.7 Nm
Drive form screw head Slotted L
Output
Position 2.x
Conductor connection
Connection method Screw connection
rigid 0.2 mm² ... 6 mm²
flexible 0.2 mm² ... 6 mm²
flexible with ferrule without plastic sleeve 0.2 mm² ... 4 mm²
flexible with ferrule with plastic sleeve 0.2 mm² ... 4 mm²
rigid (AWG) 24 ... 10
Stripping length 10 mm
Tightening torque 0.6 Nm ... 0.8 Nm
Drive form screw head Slotted L
Signal
Position 3.x
Conductor connection
Connection method Push-in connection
rigid 0.2 mm² ... 1 mm²
flexible 0.2 mm² ... 1.5 mm²
flexible with ferrule without plastic sleeve 0.2 mm² ... 1.5 mm²
flexible with ferrule with plastic sleeve 0.2 mm² ... 0.75 mm²
rigid (AWG) 24 ... 16
Stripping length 8 mm
Types of signaling LED
Floating signal contact
Active signal output Out1 (digital, configurable)
Active signal output Out2 (analog, configurable)
Remote contact
Signal ground SGnd
Signal threshold > 100 % (LED lights up yellow, output power > 480 W)
> 75 % (LED lights up green, output power > 360 W)
> 50 % (LED lights up green, output power > 240 W)
> 0.9 x USet (LED lights up green)
< 0.9 x USet (LED flashes green)
> 0.8 x UInNom (LED off)
< 0.8 x UInNom (LED lights up yellow)
Number of phases 1.00
Insulation voltage input/output 4 kV DC (type test)
2 kV DC (routine test)
Switching frequency 190 kHz ... 220 kHz (Auxiliary converter stage)
67 kHz ... 135 kHz (Main converter stage)
Product type DC/DC converters
Product family QUINT POWER
MTBF (IEC 61709, SN 29500) > 1034000 h (25 °C)
> 577000 h (40 °C)
> 229000 h (60 °C)
Insulation characteristics
Protection class Special with SELV input and output
Degree of pollution 2
Life expectancy (electrolytic capacitors)
Current 10 A
Temperature 40 °C
Time 413707 h
Additional text 24 V DC
Life expectancy (electrolytic capacitors)
Current 20 A
Temperature 40 °C
Time 139340 h
Additional text 24 V DC
Life expectancy (electrolytic capacitors)
Current 20 A
Temperature 30 °C
Time 278680 h
Additional text 24 V DC
Width 70 mm
Height 130 mm
Depth 125 mm
Installation dimensions
Installation distance right/left (active) 15 mm / 15 mm
Installation distance right/left (passive) 5 mm / 5 mm
Installation distance top/bottom (active) 50 mm / 50 mm
Installation distance top/bottom (passive) 50 mm / 50 mm
Alternative assembly
Width 122 mm
Height 130 mm
Depth 73 mm
Mounting type DIN rail mounting
Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
With protective coating yes
Flammability rating according to UL 94 (housing / terminal blocks) V0
Housing material Metal
Hood version Stainless steel X6Cr17
Side element version Aluminum
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport) -40 °C ... 85 °C
Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
Climatic class 3K22 (in accordance with EN 60721-3-3)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min, resonance frequency 2.3g, 90 min
Overvoltage category
EN 61010-1 II (≤ 5000 m)
EN 62477-1 III (≤ 5000 m)
Safety for measurement, control, and laboratory equipment
Standards/specifications IEC 61010-1
Protective extra-low voltage
Standards/specifications EN 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Explosive atmospheres
Standards/specifications IEC 60079-0
IEC 60079-7
IEC 60079-11
IEC 60079-15
Mains voltage dips
Standards/specifications EN 61000-4-29
Railway applications
Standards/specifications EN 50121-3-2
EN 50121-4
IEC 62236-3-2
IEC 62236-4
UL
Identification UL Listed UL 61010-1
UL
Identification UL Listed UL 61010-2-201
UL
Identification UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
CSA
Identification CAN/CSA-C22.2 No. 61010-1-12
CSA
Identification CAN/CSA-IEC 61010-2-201:14
SIQ
Identification Type tested (type approved)
SIQ
Identification CB scheme (IEC 61010-1, IEC 61010-2-201)
ATEX
Identification SIQ 21 ATEX 287 X
 II 3 G Ex ec ic nC IIC T4 Gc
IECEx
Identification IECEx SIQ 20.0002X
Ex ec ic nC IIC T4 Gc
Identification SIL 2
UKEX
Identification EXV21UKEX1073X
Shipbuilding
Identification DNV
Shipbuilding
Identification ABS
Shipbuilding
Identification LR
Shipbuilding
Identification NK
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
EMC requirements, power plant IEC 61850-3
EN 61000-6-5
Conducted noise emission EN 55016
EN 61000-6-3 (Class B)
Noise emission Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
Noise emission EN 55016
EN 61000-6-3 (Class B)
DNV GL conducted interference Class B
Additional text Bridge and deck area
DNV GL noise radiation Class B
Additional text Bridge and deck area
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Comments Criterion A
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m (Test Level 3)
Frequency range 1 GHz ... 6 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 3 - asymmetrical)
Comments Criterion A
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)
Power frequency magnetic field
Standards/regulations EN 61000-4-8
Frequency 16.7 Hz
50 Hz
60 Hz
Test field strength 100 A/m
Additional text 60 s
Comments Criterion A
Frequency 50 Hz
60 Hz
Frequency range 50 Hz ... 60 Hz
Test field strength 1 kA/m
Additional text 3 s
Comments Criterion A
Frequency 0 Hz
Test field strength 300 A/m
Additional text DC, 60 s
Comments Criterion A
Voltage dips
Standards/regulations EN 61000-4-29
Voltage 24 V DC
Voltage dip 70 %
Time 100 ms
Additional text Test Level 2
Comments Criterion A
Voltage dip 40 %
Time 100 ms
Additional text Test Level 2
Comments Criterion B
Voltage dip 0 %
Time 50 ms
Additional text Test Level 2
Comments Criterion B
Pulse-shape magnetic field
Standards/regulations EN 61000-4-9
Test field strength 1000 A/m
Comments Criterion A
Asymmetrical conducted disturbance variables
Standards/regulations EN 61000-4-16
Test level 1 15 Hz 150 Hz (Test Level 3)
Voltage 10 V 1 V
Test level 2 150 Hz 1.5 kHz (Test Level 3)
Voltage 1 V
Test level 3 1.5 kHz 15 kHz (Test Level 3)
Voltage 1 V 10 V
Test level 4 15 kHz 150 kHz (Test Level 3)
Voltage 10 V
Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Voltage 10 V (Permanent)
Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
Voltage 100 V (1 s)
Comments Criterion A
Alternating component of direct voltage
Standards/regulations EN 61000-4-17
Alternating component 10 % (UN)
Frequency 50 Hz
100 Hz
150 Hz
Comments Criterion A
Alternating component 10 % (UN)
Frequency 300 Hz
Comments Criterion A
Attenuated oscillating wave
Standards/regulations EN 61000-4-18
Input, output (test level 1) 1 MHz (Test Level 2 - symmetrical)
Voltage 0.5 kV
Input, output (test level 2) 1 MHz (Test Level 2 - asymmetrical)
Voltage 1 kV
Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
Voltage 0.5 kV
Signals (test level 1) 1 MHz (Test Level 2 - symmetrical)
Voltage 0.5 kV
Signals (test level 2) 1 MHz (Test Level 2 - asymmetrical)
Voltage 1 kV
Comments Criterion A
Attenuated oscillating magnetic field
Standards/regulations EN 61000-4-10
Test field strength 100 A/m
Test level 1 100 kHz
Test field strength 100 A/m
Test level 2 1 MHz
Comments Criterion A
Criteria
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

Sản phẩm thịnh hành

Máy nén Embraco NTX6238U 843JA72 2172W

Máy nén Embraco NTX6238U 843JA72 2172W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2446W

Máy nén Embraco NTX6238U 843JA72 2446W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2735W

Máy nén Embraco NTX6238U 843JA72 2735W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2841W

Máy nén Embraco NTX6238U 843JA72 2841W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 1868W

Máy nén Embraco NTX6233U 843FA72 1868W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2088W

Máy nén Embraco NTX6233U 843FA72 2088W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2348W

Máy nén Embraco NTX6233U 843FA72 2348W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2425W

Máy nén Embraco NTX6233U 843FA72 2425W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1702W

Máy nén Embraco NTX6225UV 843HD72 1702W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1978W

Máy nén Embraco NTX6225UV 843HD72 1978W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2161W

Máy nén Embraco NTX6225UV 843HD72 2161W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2236W

Máy nén Embraco NTX6225UV 843HD72 2236W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ: