category Tất cả danh mục
Menu
      QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH     -     Uninterruptible power supply   Phoenix Contact

QUINT-UPS/ 24DC/ 24DC/ 5/1.3AH - Uninterruptible power supply Phoenix Contact

Mã sản phẩm: 2320254

Danh mục: PHOENIX CONTACT, Supply, charge, and protect Phoenix Contact,

Uninterruptible energy supply with IQ technology and integrated energy storage for DIN rail mounting, input 24 V DC, output: 24 V DC / 5 A, energy storage: lead AGM 1.2 Ah, incl. mounted UTA 107/30 universal DIN rail adapter

Liên hệ mua hàng

Hãng sản xuất: PHOENIX CONTACT

Chất lượng: Mới 100%

Bảo hành: Chính hãng

Chứng từ: CO/CQ, hóa đơn VAT

Liên hệ(SĐT/Zalo): 0933612627

Product type DC UPS with integrated energy storage
Product family QUINT UPS ‒ UPS with integrated energy storage
Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
IQ technology Yes
MTBF (IEC 61709, SN 29500) > 806000 h (40 °C)
Insulation characteristics
Protection class III
Degree of pollution 2
Life expectancy (electrolytic capacitors)
Time 316800 h
DC operation
Input voltage 24 V DC
Input voltage range 18 V DC ... 30 V DC
Input voltage range DC 18 V DC ... 30 V DC
Voltage type of supply voltage DC
Buffer period 50 min. (1 A)
5 min. (5 A)
Current consumption 9.3 A (24 V DC)
9.7 mA
1.7 A
7 A
Fixed backup threshold ≤ 22.6 V DC
Efficiency > 97.1 % (Mains operation, with charged energy storage)
97.31 %
Nominal output voltage 24 V DC
Output voltage range 18 V DC ... 30 V DC
Nominal output current (IN) 5 A (0 °C ... 40 °C)
Output current limit > 7.5 A (Battery operation)
Bridging time 360 s
Derating 60 °C ... 70 °C (2.5%/K)
Output power 120 W
Power dissipation 2.5 W (Mains operation)
2.7 W (Mains operation)
1.9 W (Mains operation)
3.3 W (Battery operation)
3.3 W (Battery operation)
4.1 W (Battery operation)
Output fuse 1x 15 A
Connection in parallel 2
Connection in series No
Mains operation
Nominal output voltage 24 V DC
Output voltage range 18 V DC ... 30 V DC (UOUT = UIN - 0,1 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 30 A (0 °C ... 40 °C)
Duration 12 ms (SFB technology)
Battery operation
Nominal output voltage 24 V DC
Output voltage range 19.2 V DC ... 27.6 V DC (UOUT = UBAT - 0,5 V DC)
Nominal output current (IN) 5 A (0 °C ... 40 °C)
POWER BOOST (IBoost) 7.5 A (0 °C ... 40 °C)
Selective Fuse Breaking (ISFB) 32.5 A (0 °C ... 40 °C)
Duration 15 ms (SFB technology)
Signal: Alarm
Output description Relay
Output voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA
Signal: Battery charge
Output description Relay
Output voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA
Signal: Battery mode
Output description Relay
Output voltage ≤ 30 V AC/DC
Continuous load current ≤ 100 mA
Signal
Continuous load current ≤ 200 mA
Nominal voltage UN 24 V DC
End-of-charge voltage 24 V DC ... 29 V DC (temperature compensated)
Charging current 0.36 A
Nominal capacity 1.2 Ah
Buffer period 50 min. (1 A)
5 min. (5 A)
Latest startup date (battery only) 3 Months (0 °C ... 20 °C)
1 Months (30 °C ... 40 °C)
Latest startup (battery only) - range 1 Months ... 3 Months (20 °C ... 30 °C)
Battery technology VRLA-AGM
Memory medium VRLA-AGM Battery 1.2 Ah
Accumulator type 2x BB Battery BP1.2-12FR (from UPS V/C-level 05)
Disposal Used batteries must not be thrown away with household waste, they should instead be disposed of in accordance with applicable national regulations.
IQ technology Yes
Temperature sensor yes
Network management Yes
Input
Connection method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Output
Connection method Screw connection
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 20
Conductor cross section AWG max. 12
Stripping length 7 mm
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Signal
Conductor cross section, rigid min. 0.2 mm²
Conductor cross section, rigid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Screw thread M4
Tightening torque, min 0.5 Nm
Tightening torque max 0.6 Nm
Interface IFS (Interface system data port)
Types of signaling LED
Relay contact
Interface/software
Signal output
Signalization designation Power In OK
Status display LED
Note on status display Static to
Static to
Signal output: Switching output
Signalization designation Alarm
Status display LED
Note on status display Static to
Color red
Note on status display Static to
Signal output: Switching output
Signalization designation Battery charge
Status display LED bar graph
Note on status display dynamic
Color red/green
Note on status display dynamic
Signal output: Switching output
Signalization designation Battery mode
Status display LED
Note on status display Static to
Color yellow
Note on status display Static to
Width 88 mm
Height 138 mm
Depth 125 mm
Installation dimensions
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
Color aluminium
Housing material Metal
Type of housing Steel sheet, zinc-plated
Side element version Galvanized sheet steel, closed
Housing material Steel sheet, zinc-plated
Ambient conditions
Degree of protection IP20
Ambient temperature (storage/transport) -20 °C ... 40 °C
Ambient temperature (charge) 0 °C ... 40 °C
Ambient temperature (discharge) -20 °C ... 50 °C
Climatic class 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation) ≤ 95 % (25 °C, non-condensing)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation) < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g tv = 90 min.
UL approvals UL/C-UL Recognized UL 60950-1
UL Listed UL 508
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Contact discharge 8 kV (Test Level 4)
Discharge in air 15 kV (Test Level 4)
Comments Criterion A
Electromagnetic HF field
Standards/regulations EN 61000-4-3
Electromagnetic HF field
Frequency range 80 MHz ... 1 GHz
Test field strength 20 V/m
Frequency range 1 GHz ... 2 GHz
Test field strength 10 V/m
Frequency range 2 GHz ... 3 GHz
Test field strength 3 V/m
Comments Criterion A
Fast transients (burst)
Standards/regulations EN 61000-4-4
Fast transients (burst)
Input 2 kV (Test Level 3 - asymmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Signal 2 kV (Test Level 4 - asymmetrical)
Comments Criterion A
Surge voltage load (surge)
Standards/regulations EN 61000-4-5
Input 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output 1 kV (Test Level 2 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Comments Criterion A
Conducted interference
Standards/regulations EN 61000-4-6
Conducted interference
I/O/S asymmetrical
Frequency range 0.15 MHz ... 80 MHz
Comments Criterion A
Voltage 10 V (Test Level 3)
Emitted interference
Standards/regulations EN 61000-6-3
Radio interference voltage in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011 EN 55011 (EN 55022) Class B, area of application: Industry and residential
Criteria
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Rail applications EN 50121-4
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard - Electrical safety EN 60950-1/VDE 0805 (SELV)
EN 61558-2-17
Mounting type DIN rail mounting
Assembly instructions alignable: horizontal 5 mm, vertical 50 mm
Mounting position horizontal DIN rail NS 35, EN 60715

Sản phẩm thịnh hành

Máy nén Embraco NTX6238U 843JA72 2172W

Máy nén Embraco NTX6238U 843JA72 2172W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2446W

Máy nén Embraco NTX6238U 843JA72 2446W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2735W

Máy nén Embraco NTX6238U 843JA72 2735W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6238U 843JA72 2841W

Máy nén Embraco NTX6238U 843JA72 2841W

Mã SP: 843JA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 1868W

Máy nén Embraco NTX6233U 843FA72 1868W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2088W

Máy nén Embraco NTX6233U 843FA72 2088W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2348W

Máy nén Embraco NTX6233U 843FA72 2348W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6233U 843FA72 2425W

Máy nén Embraco NTX6233U 843FA72 2425W

Mã SP: 843FA72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1702W

Máy nén Embraco NTX6225UV 843HD72 1702W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 1978W

Máy nén Embraco NTX6225UV 843HD72 1978W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2161W

Máy nén Embraco NTX6225UV 843HD72 2161W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ:

Máy nén Embraco NTX6225UV 843HD72 2236W

Máy nén Embraco NTX6225UV 843HD72 2236W

Mã SP: 843HD72

Thương hiệu: Embraco

Xuất xứ: